1S2: Difference between revisions

419 bytes added ,  11 September 2023
no edit summary
No edit summary
No edit summary
 
(18 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar  
title=Tektronix 1S2|
|manufacturer=Tektronix
summary=Sampling system/TDR|
|series=500-series scopes
image=1s2_front.jpg |  
|type=1S2
caption=1S2 front view|
|summary=Sampling system/TDR
introduced=1967 |
|image=Tek 1s2 front.jpg  
discontinued=1973 |
|caption=1S2 front view
series=[[500-series scopes]]|
|introduced=1967
manuals=
|discontinued=1973
* [[Media:070-0889-00.pdf|1S2 manual (PDF, sn 1990 and up)]]
|designers=Chuck Edgar;Gene Cowan
* [http://www.pa4tim.nl/wp-content/uploads/2012/01/1S2calibrationPA4TIM.pdf 1S2 Calibration Guide by Fred Schneider, PA4TIM]
|manuals=
* [http://www.pa4tim.nl/?p=3016 1S2 Page on the Website of Fred Schneider, PA4TIM]
* [[Media:070-0889-00.pdf|1S2 manual]] (S/N 1990+, OCR)
 
* ''Manual needed for sn below 1990 [[Category:Manual needed]]''
* [[Media:tek_manual_070-0889-00.pdf|1S2 manaul (PDF, sn 1990 and up, OCR)]]
* [[Media:Tek 1s2 fcp june 1966.pdf‎|Tektronix 1S2 Factory Calibration Procedure, June 1966]]
* [[Media:Tek 1s2 fcp aug 1968.pdf‎|Tektronix 1S2 Factory Calibration Procedure, August 1968]]
* [[Media:Tek 1s2 cal outline.pdf|Tektronix 1S2 Calibration Outline]]
<!-- * [[Media:1S2_calibration_guide.pdf|1S2 Calibration Guide by Fred Schneider, PA4TIM]] -->
}}
}}
The '''Tektronix 1S2''' is a [[sampling oscilloscope|sampling]]/TDR plug-in for [[500-series scopes]], [[introduced in 1967]] and sold through 1972.
The '''Tektronix 1S2''' is a [[sampling oscilloscope|sampling]]/TDR plug-in for [[500-series scopes]], [[introduced in 1967]] and sold through 1972.
[[Chuck Edgar]] designed the sweep circuitry and [[Gene Cowan]] designed the vertical circuitry.


Like the [[1S1]], it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed X-Y display.
Like the [[1S1]], it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed X-Y display.
Line 23: Line 27:
The other puts out a slower 1 V pulse.  The sampling bridge is a feed-through type.   
The other puts out a slower 1 V pulse.  The sampling bridge is a feed-through type.   


For TDR measurements, the signal from one of the internal pulsers is fed through the sampler, and out to the the transmission line being tested.   
For TDR measurements, the signal from one of the internal pulsers is fed through the sampler, and out to the transmission line being tested.   
Returning pulses are detected as they pass back through the sampler, and they are reabsorbed by the 50 Ω impedance of the pulser.   
Returning pulses are detected as they pass back through the sampler, and they are reabsorbed by the 50 Ω impedance of the pulser.   


Line 40: Line 44:
==Links==
==Links==


* [[Media:062-1244-00.pdf | Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts]], James A. Strickland, 1969. pages. PDF, OCR, 6.2 MB
* [https://www.pa4tim.nl/wp-content/uploads/2012/01/1S2calibrationPA4TIM.pdf 1S2 Calibration Guide by Fred Schneider, PA4TIM]
* [https://www.pa4tim.nl/?p=3016 1S2 Page on the Website of Fred Schneider, PA4TIM]
* [[Media:062-1244-00.pdf | Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts]], James A. Strickland, 1969. OCR, 6.2 MB
* [[Media:Service Scope 45 Aug 1967.pdf  | Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory]]
* [[Media:Service Scope 45 Aug 1967.pdf  | Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory]]
* [[Media:Service Scope 38 Jun 1966.pdf | Service Scope No. 38, June 1966 - Tektronix Type 1S2 Makes Reflectometry Easy]]
* [[Media:Service Scope 38 Jun 1966.pdf | Service Scope No. 38, June 1966 - Tektronix Type 1S2 Makes Reflectometry Easy]]
* [http://w140.com/kurt/50_years_sampling.pdf 50 Years of RF and Microwave Sampling, Mark Kahrs]
* [https://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR]
* [http://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR]


==Pictures==
==Pictures==
Line 61: Line 66:
Tek 1s2 e 7.jpg
Tek 1s2 e 7.jpg
Tek 1s2 regulated ps.png|Internal Regulated Power Supply
Tek 1s2 regulated ps.png|Internal Regulated Power Supply
Tek 1s2 rear.jpg|rear
</gallery>
</gallery>


Line 69: Line 75:
[[Category:500 series plugins]]
[[Category:500 series plugins]]
[[Category:GR874]]
[[Category:GR874]]
[[Category:Manual needed]]