1S2: Difference between revisions

17 bytes removed ,  11 September 2023
no edit summary
No edit summary
No edit summary
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Plugin Sidebar | designers=|
{{Plugin Sidebar  
manufacturer=Tektronix | type=1S2|
|manufacturer=Tektronix
summary=Sampling system/TDR|
|series=500-series scopes
image=1s2_front.jpg |  
|type=1S2
caption=1S2 front view|
|summary=Sampling system/TDR
introduced=1967 |
|image=Tek 1s2 front.jpg  
discontinued=1973 |
|caption=1S2 front view
series=500-series scopes |
|introduced=1967
manuals=
|discontinued=1973
* [[Media:070-0889-00.pdf|1S2 manual (PDF, sn 1990 and up, OCR)]]
|designers=Chuck Edgar;Gene Cowan
* [http://www.pa4tim.nl/wp-content/uploads/2012/01/1S2calibrationPA4TIM.pdf 1S2 Calibration Guide by Fred Schneider, PA4TIM]
|manuals=
* [http://www.pa4tim.nl/?p=3016 1S2 Page on the Website of Fred Schneider, PA4TIM]
* [[Media:070-0889-00.pdf|1S2 manual]] (S/N 1990+, OCR)
* ''Manual needed for sn below 1990 [[Category:Manual needed]]''
* [[Media:Tek 1s2 fcp june 1966.pdf‎|Tektronix 1S2 Factory Calibration Procedure, June 1966]]
* [[Media:Tek 1s2 fcp june 1966.pdf‎|Tektronix 1S2 Factory Calibration Procedure, June 1966]]
* [[Media:Tek 1s2 fcp aug 1968.pdf‎|Tektronix 1S2 Factory Calibration Procedure, August 1968]]
* [[Media:Tek 1s2 fcp aug 1968.pdf‎|Tektronix 1S2 Factory Calibration Procedure, August 1968]]
* [[:Category:Manual needed|Manual needed for sn below 1990]]
* [[Media:Tek 1s2 cal outline.pdf|Tektronix 1S2 Calibration Outline]]
* [[Media:Tek 1s2 cal outline.pdf|Tektronix 1S2 Calibration Outline (PDF, OCR)]]
<!-- * [[Media:1S2_calibration_guide.pdf|1S2 Calibration Guide by Fred Schneider, PA4TIM]] -->
<!-- * [[Media:1S2_calibration_guide.pdf|1S2 Calibration Guide by Fred Schneider, PA4TIM (PDF, OCR)]] -->
 
}}
}}
The '''Tektronix 1S2''' is a [[sampling oscilloscope|sampling]]/TDR plug-in for [[500-series scopes]], [[introduced in 1967]] and sold through 1972.
The '''Tektronix 1S2''' is a [[sampling oscilloscope|sampling]]/TDR plug-in for [[500-series scopes]], [[introduced in 1967]] and sold through 1972.
[[Chuck Edgar]] designed the sweep circuitry and [[Gene Cowan]] designed the vertical circuitry.


Like the [[1S1]], it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed X-Y display.
Like the [[1S1]], it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed X-Y display.
Line 44: Line 44:
==Links==
==Links==


* [[Media:062-1244-00.pdf | Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts]], James A. Strickland, 1969. pages. PDF, OCR, 6.2 MB
* [https://www.pa4tim.nl/wp-content/uploads/2012/01/1S2calibrationPA4TIM.pdf 1S2 Calibration Guide by Fred Schneider, PA4TIM]
* [https://www.pa4tim.nl/?p=3016 1S2 Page on the Website of Fred Schneider, PA4TIM]
* [[Media:062-1244-00.pdf | Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts]], James A. Strickland, 1969. OCR, 6.2 MB
* [[Media:Service Scope 45 Aug 1967.pdf  | Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory]]
* [[Media:Service Scope 45 Aug 1967.pdf  | Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory]]
* [[Media:Service Scope 38 Jun 1966.pdf | Service Scope No. 38, June 1966 - Tektronix Type 1S2 Makes Reflectometry Easy]]
* [[Media:Service Scope 38 Jun 1966.pdf | Service Scope No. 38, June 1966 - Tektronix Type 1S2 Makes Reflectometry Easy]]
* [http://w140.com/kurt/50_years_sampling.pdf 50 Years of RF and Microwave Sampling, Mark Kahrs]
* [https://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR]
* [http://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR]


==Pictures==