3T2: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(4 intermediate revisions by 3 users not shown)
Line 3: Line 3:
|series=560-series scopes
|series=560-series scopes
|type=3T2
|type=3T2
|summary=Sampling Timebase
|summary=Random sampling sweep plug-in
|image=Tek 3t2 front.jpg
|image=Tek 3t2 front.jpg
|caption=Tektronix 3T2
|caption=Tektronix 3T2
Line 9: Line 9:
|discontinued=(?)
|discontinued=(?)
|manuals=
|manuals=
* [[Media:070-0631-00.pdf|Tektronix 3T2 Manual]]<br /><small>Alternate: [http://bama.edebris.com/download/tek/3t2/3t2.djvu DjVu @ BAMA]</small>
* [[Media:070-0631-00.pdf|Tektronix 3T2 Manual]] (OCR)
* [[Media:Tek 3t2 fcp aug 1967.pdf|Tektronix Factory Calibration Procedure]]
* [[Media:Tek 3t2 fcp aug 1967.pdf|Tektronix Factory Calibration Procedure]]
* [[Media:Tek 3t2 cal outline.pdf|Tektronix 3T2 Calibration Outline]] (OCR)
* [[Media:Tek 3t2 cal outline.pdf|Tektronix 3T2 Calibration Outline]] (OCR)
Line 21: Line 21:
UHF SYNC works up to 3 GHz.   
UHF SYNC works up to 3 GHz.   
The amount of jitter depends on the mode of operation.   
The amount of jitter depends on the mode of operation.   
The lowest jitter, specified to be less than 2 ps, is obtained with  
The lowest jitter, specified to be less than 20 ps, is obtained with an external 50 Ω trigger source of at least 150 mV.   
an external 50 Ω trigger source of at least 150 mV.   


==Links==
==Links==

Latest revision as of 18:15, 7 December 2023

Tektronix 3T2
Random sampling sweep plug-in
Tektronix 3T2

Compatible with 560-series scopes

Produced from 1967 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3T2 is a sampling time-base plug-in for 560-series scopes.

Specifications

Triggering works up to 100 MHz. The 3T2 has a random sampling mode. UHF SYNC works up to 3 GHz. The amount of jitter depends on the mode of operation. The lowest jitter, specified to be less than 20 ps, is obtained with an external 50 Ω trigger source of at least 150 mV.