P6016
The Tektronix P6016 is a passive current probe for oscilloscopes. It can be used with passive termination or a type 131 probe amplifier.
Key Specifications
Maximum current | 15 Ap-p |
---|---|
DC saturation | 0.5 A |
— With passive termination — | |
Sensitivity | 2 mA/mV or 10 mA/mV selectable |
Rise time | 18 ns (eq. 20 MHz -3 dB) |
Lower frequency limit | 850 Hz at 2 mA/mV, 230 Hz at 10 mA/mV |
Delay time | 12 ns typ. |
— With 131 amplifier — | |
Sensitivity | 1 mA/Div to 1 A/Div, 1-2-5 |
Noise | 0.1 mAp-p |
Rise time | 20 ns (eq. 17 MHz -3 dB) |
Lower frequency limit | 50 Hz |
Delay time | 32 ns typ. |
Manuals