067-0916-00: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Tags: Mobile edit Mobile web edit
 
(9 intermediate revisions by 5 users not shown)
Line 1: Line 1:
{{TM500 | mfg=Tektronix | type=067-0916-00 | function=video amplitude calibration fixture | class=calibration | image=Tek_067-0916-00 2.jpg | introduced=(?) | discontinued=(?) | manuals=
{{TM500  
* [[Media:070-3643-00.pdf|Tektronix 067-0916-00 Manual (PDF, OCR)]]
|mfg=Tektronix  
* [http://w140.com/tek_067_0916_00_summary.pdf Tektronix 067-0916-00 Summary (PDF)]
|type=067-0916-00  
* [[Media:ServiceTekNotes 20 Nov 1981.pdf|ServiceTekNotes Issue 20, Nov 1981 (pp.13+)]]
|function=video amplitude calibration fixture  
* [[Media:070-3752-00.pdf|Tektronix 015-0407-00 Manual (PDF, OCR)]]
|class=calibration  
|image=VideoAmplitudeCalibrationFixture_Front.jpg  
|introduced=(?)  
|discontinued=(?)  
|designers=
|manuals=
* [[Media:070-3643-00.pdf|Tektronix 067-0916-00 Manual]] (OCR)
* [[Media:070-3752-00.pdf|Tektronix 015-0407-00 Manual]] (OCR)
* [https://w140.com/tek_067_0916_00_summary.pdf Tektronix 067-0916-00 Summary]
}}
}}
It measures waveform characteristics of video signals.
It is used for measuring and calibrating luminance and chrominance waveform characteristics of video signal generators and waveform monitors.  


The 067-0916-00 came with a Subcarrier Harmonic Rejection Filter ([[015-0407-00]]), 0.6% attenuator ([[011-0134-00]]), and precision terminator ([[011-0102-01]]).
{{MissingSpecs}}
The 067-0916-00 (VAC) generates a precise square wave from its low impedance output with a resolution of 0.1 mV and an accuracy of 0.05% from 0 to 999.9 mV.
Color standards NTSC, PAL, PAL-M, and SECAM along with other signal parameters such as half or full amplitude and many others may be selected.


{{MissingSpecs}}
The 067-0916-00 (VAC) came with a subcarrier harmonic rejection filter ([[015-0407-00]]), 0.6% attenuator ([[011-0134-00]]), and precision terminator ([[011-0102-01]]).
 
==Links==
* [[Media:ServiceTekNotes 20 Nov 1981.pdf|ServiceTekNotes Issue 20, Nov 1981 (pp.13+)]]


==Pictures==
==Pictures==

Latest revision as of 03:46, 18 February 2024

Tektronix 067-0916-00
video amplitude calibration fixture
Tektronix 067-0916-00

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0916-00 is a video amplitude calibration fixture plug-in for the TM500 system.

It is used for measuring and calibrating luminance and chrominance waveform characteristics of video signal generators and waveform monitors.

Key Specifications

  • please add

The 067-0916-00 (VAC) generates a precise square wave from its low impedance output with a resolution of 0.1 mV and an accuracy of 0.05% from 0 to 999.9 mV. Color standards NTSC, PAL, PAL-M, and SECAM along with other signal parameters such as half or full amplitude and many others may be selected.

The 067-0916-00 (VAC) came with a subcarrier harmonic rejection filter (015-0407-00), 0.6% attenuator (011-0134-00), and precision terminator (011-0102-01).

Links