Line 5: Line 5:
caption=1S2 front view|
caption=1S2 front view|
introduced=1967 |
introduced=1967 |
discontinued=1972 |
discontinued=1973 |
series=[[500-series scopes]]|
series=[[500-series scopes]]|
manuals=
manuals=
Line 24: Line 24:
Waveform output can be to the CRT of the mainframe and/or to a plotter or low-speed data acquisition device via banana connectors on the front of the 1S2.   
Waveform output can be to the CRT of the mainframe and/or to a plotter or low-speed data acquisition device via banana connectors on the front of the 1S2.   


The 1S2 was [[introduced in 1967]] and was sold through 1971 or 1972.
The 1S2 was [[introduced in 1967]] and was sold through 1972.


The interface between the GR-874 connector and the printed circuit board is described in US Patent 3,426,311.
==Links==
==Links==


* [[Media:062-1244-00.pdf | Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts]], James A. Strickland, 1969. pages. PDF, OCR, 6.2 MB
* [[Media:062-1244-00.pdf | Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts]], James A. Strickland, 1969. pages. PDF, OCR, 6.2 MB
* [[Media:Service Scope 45 Aug 1967.pdf  | Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory]]
* [[Media:Service Scope 45 Aug 1967.pdf  | Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory]]
* [[Media:Service Scope 38 Jun 1966.pdf | Service Scope No. 38, June 1966 - Tektronix Type 1S2 Makes Reflectometry Easy]]
* [http://w140.com/kurt/50_years_sampling.pdf 50 Years of RF and Microwave Sampling, Mark Kahrs]
* [http://w140.com/kurt/50_years_sampling.pdf 50 Years of RF and Microwave Sampling, Mark Kahrs]
* [http://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR]
* [http://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR]

Revision as of 13:51, 5 November 2017

Template:Plugin Sidebar 2 The Tektronix 1S2 is a sampling/TDR plug-in for 500-series scopes. Like the 1S1, it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed display.

Unlike the 1S1, it contains pulsers that allows it to perform time-domain reflectometry (TDR) measurements. The 1S2 has two 50 Ω pulsers, one of which is active at a time. One puts out a 250 mV pulse with 50 ps rise time. The other puts out a slower 1 V pulse. The sampling bridge is a feed-through type.

For TDR measurements, the signal from one of the internal pulsers is fed through the sampler, and out to the the transmission line being tested. Returning pulses are detected as they pass back through the sampler, and they are reabsorbed by the 50 Ω impedance of the pulser.

Waveform output can be to the CRT of the mainframe and/or to a plotter or low-speed data acquisition device via banana connectors on the front of the 1S2.

The 1S2 was introduced in 1967 and was sold through 1972.

The interface between the GR-874 connector and the printed circuit board is described in US Patent 3,426,311.

Links

Pictures