213: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
(9 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar |
title=Tektronix 213 |
title=Tektronix 213 |
image=Tek213-front-1.jpg |
image=Tektronix 213DMM pic 2.jpg |
caption=Tektronix 213, front view |
caption=Tektronix 213, front view |
introduced=1975 |
introduced=1975 |
Line 7: Line 7:
summary=Miniature portable 1 MHz oscilloscope and TRMS digital multimeter |
summary=Miniature portable 1 MHz oscilloscope and TRMS digital multimeter |
manuals=
manuals=
* [[Media:070-1481-00.pdf|Tektronix 213 Service Manual, 1989 Rev.]] (PDF, OCR, 76MB)
<small>
'''Modifications'''
* [[Media:050-0811-01.pdf|Replacement of U335 (Trigger &amp; Sweep Generator IC)]]
</small>
}}
}}
The '''Tektronix 213''' is a miniature portable oscilloscope [[introduced in 1975]].   
The '''Tektronix 213''' is a miniature portable oscilloscope [[introduced in 1975]].   
Line 14: Line 19:
The 213 provides true RMS voltage and current measurements.
The 213 provides true RMS voltage and current measurements.
It is battery or AC line powered.
It is battery or AC line powered.
* [http://w140.com/kurt/tek_new_products_mar-apr_1975.pdf New Products Mar/Apr 1975]


{{BeginSpecs}}
{{BeginSpecs}}
{{SpecGroup | ''Multimeter Section''  }}
{{SpecGroup | ''Multimeter Section''  }}
{{Spec | DC Volts | 0.1 V to 1000 V,  Input Resistance: 10 MΩ <br />Accuracy,  0.1 V & 1 V:  ±0.1%, ±3 counts; 10 V & 100 V: ±0.15%, ±1 count; 1000 V: ±0.2%, ±1 count}}
{{Spec | DC Volts | 0.1 V to 1000 V,  Input Resistance: 10 MΩ <br />Accuracy,  0.1 V & 1 V:  ±0.1%, ±3 counts; 10 V & 100 V: ±0.15%, ±1 count; 1000 V: ±0.2%, ±1 count}}
{{Spec | True RMS Volts | DC Volts | 0.1 V to 1000 V,  Input Resistance: 10 MΩ <br />Accuracy, 0.1 V: ±2.5% (DC); ±1.5% (40 Hz – 4 KHz); ±3.5% (4 KHz 40 KHz);  1, 10, 100 V:  ±2% (DC); ±1% (40 Hz – 40 KHz); 1000 V:  ±2% (DC); ±1% (40 Hz – 4KHz); ±2% (4 KHz 40 KHz) }}
{{Spec | True RMS Volts | DC Volts | 0.1 V to 1000 V,  Input Resistance: 10 MΩ <br />Accuracy, 0.1 V: ±2.5% (DC); ±1.5% (40 Hz – 4 kHz); ±3.5% (4 kHz 40 kHz);  1, 10, 100 V:  ±2% (DC); ±1% (40 Hz – 40 kHz); 1000 V:  ±2% (DC); ±1% (40 Hz – 4 kHz); ±2% (4 kHz 40 kHz) }}
{{Spec | DC Current | 0.1 to 1000 mA <br />Accuracy: 0.1 mA:  ±0.5%, ±3 counts; 1 mA – 1000 mA: ±0.25%, ±3 counts }}
{{Spec | DC Current | 0.1 to 1000 mA <br />Accuracy: 0.1 mA:  ±0.5%, ±3 counts; 1 mA – 1000 mA: ±0.25%, ±3 counts }}
{{Spec | True RMS Current | 0.1 to 1000 mA <br />Accuracy, 0.1 mA:  ±2.5%, ±5 counts (DC); ±1.5%, ±5 counts (40 Hz – 4 KHz); ±4.5%, ±5 counts (4 KHz - 40 KHz);  1 mA – 1000 mA: ±2.5%, ±5 counts (DC); ±1.5%, ±5 counts (40 Hz – 4 KHz); ±3.5%,±5 counts (4 KHz - 40 KHz) }}
{{Spec | True RMS Current | 0.1 to 1000 mA <br />Accuracy, 0.1 mA:  ±2.5%, ±5 counts (DC); ±1.5%, ±5 counts (40 Hz – 4 kHz); ±4.5%, ±5 counts (4 kHz − 40 kHz);  1 mA – 1000 mA: ±2.5%, ±5 counts (DC); ±1.5%, ±5 counts (40 Hz – 4 kHz); ±3.5%,±5 counts (4 kHz − 40 kHz) }}
{{Spec | Current range input resistance | 0.1 mA: 1000 Ω; 1 mA: 100 Ω; 10 mA: 10.2 Ω; 100 mA: 1.2 Ω; 1000 mA: 0.3 Ω }}
{{Spec | Current range input resistance | 0.1 mA: 1000 Ω; 1 mA: 100 Ω; 10 mA: 10.2 Ω; 100 mA: 1.2 Ω; 1000 mA: 0.3 Ω }}
{{Spec | Resistance | 1 KΩ: ±0.5%, ±3 counts; 10 KΩ – 1 MΩ:  ±0.5%, ±1 count; 10 MΩ: ±1%, ±1 count }}
{{Spec | Resistance | 1 KΩ: ±0.5%, ±3 counts; 10 KΩ – 1 MΩ:  ±0.5%, ±1 count; 10 MΩ: ±1%, ±1 count }}
Line 29: Line 32:
{{Spec | Bandwidth (Voltage) | DC – 1 MHz (at 10 mV/Div and below, 400 kHz) }}
{{Spec | Bandwidth (Voltage) | DC – 1 MHz (at 10 mV/Div and below, 400 kHz) }}
{{Spec | Current ranges | 5 µA/Div to 100 mA/Div, ±3% }}
{{Spec | Current ranges | 5 µA/Div to 100 mA/Div, ±3% }}
{{Spec | Bandwidth (Current) | DC – 200 kHz (5 µA/Div – 10 µA/Div); DC – 400 kHz (20 µA/Div – 200 mA/Div) }}
{{Spec | Bandwidth (Current) | DC – 200 kHz (5 µA/Div – 10 μA/Div); DC – 400 kHz (20 μA/Div – 200 mA/Div) }}
{{Spec | Input resistance | 10 MΩ // 150 pF (5 mV/Div – 1 V/Div), 100 pF (2 V/Div to – 100 V/Div) }}
{{Spec | Input resistance | 10 MΩ // 150 pF (5 mV/Div – 1 V/Div), 100 pF (2 V/Div to – 100 V/Div) }}
{{Spec | Rise time |  875 ns (5mV 10mV/DIV); 350 ns (20 mV – 100 V/Div) }}
{{Spec | Rise time |  875 ns (5 mV/Div 10 mV/Div); 350 ns (20 mV/Div – 100 V/Div) }}
{{Spec | Sweep |  500 ms/Div – 2 µs/Div, ±5% (magnified or unmagnified) }}
{{Spec | Sweep |  500 ms/Div – 2 µs/Div, ±5% (magnified or unmagnified) }}
{{Spec | Batteries |  2 &times; “D” NiCd cells }}
{{Spec | Batteries |  2 &times; “D” NiCd cells }}
Line 41: Line 44:


==Links==
==Links==
* [http://w140.com/kurt/tek_new_products_mar-apr_1975.pdf New Products Mar/Apr 1975]
* [http://www.eevblog.com/2014/06/11/eevblog-628-tektronix-213-vintage-portable-oscilloscope-teardown/ EEVblog #628 – Tektronix 213 Vintage Portable Oscilloscope Teardown Video] and [https://www.flickr.com/photos/eevblog/14394189202/ Photo Set]
* [http://www.eevblog.com/2014/06/11/eevblog-628-tektronix-213-vintage-portable-oscilloscope-teardown/ EEVblog #628 – Tektronix 213 Vintage Portable Oscilloscope Teardown Video] and [https://www.flickr.com/photos/eevblog/14394189202/ Photo Set]
* [https://www.youtube.com/watch?v=fPmQ9Ce4TL0 Tektronix 213 DMM Repair Progress video]
* [https://www.youtube.com/watch?v=fPmQ9Ce4TL0 Tektronix 213 DMM Repair Progress video]
Line 52: Line 56:
Tek213-front-1.jpg | Tek 213 front
Tek213-front-1.jpg | Tek 213 front
Tektronix 213DMM pic 2.jpg|In DMM mode
Tektronix 213DMM pic 2.jpg|In DMM mode
200 series compared.jpg | Tek [[214]] (top), [[213]] (center) and [[211]] (bottom) stacked
213 compared to 585.jpg | Tek 213 size comparison with 500 series plug-in bay (in a [[585]])
213-Stefan-140333.jpg | 213 with pouch
213-Stefan-140333.jpg | 213 with pouch
213-Stefan-140342.jpg | right side
213-Stefan-140342.jpg | right side
Line 81: Line 87:


[[Category:200 series scopes]]
[[Category:200 series scopes]]
[[Category:Portable scopes]]


[[Category:Specifications needed]]
[[Category:Specifications needed]]
[[Category:Manual needed]]
[[Category:Manual needed]]

Revision as of 01:20, 17 October 2019

{{{manufacturer}}} 
Miniature portable 1 MHz oscilloscope and TRMS digital multimeter
Tektronix 213, front view

Produced from 1975 to 1988

Manuals

Modifications

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 213 is a miniature portable oscilloscope introduced in 1975. It combines a 3½-digit DMM and a 1 MHz single channel scope in one unit. The maximum sweep rate is 0.4 μs/div with ×10 sweep magnifier.

The 213 provides true RMS voltage and current measurements. It is battery or AC line powered.

Key Specifications

     — Multimeter Section
DC Volts 0.1 V to 1000 V, Input Resistance: 10 MΩ
Accuracy, 0.1 V & 1 V: ±0.1%, ±3 counts; 10 V & 100 V: ±0.15%, ±1 count; 1000 V: ±0.2%, ±1 count
True RMS Volts DC Volts
DC Current 0.1 to 1000 mA
Accuracy: 0.1 mA: ±0.5%, ±3 counts; 1 mA – 1000 mA: ±0.25%, ±3 counts
True RMS Current 0.1 to 1000 mA
Accuracy, 0.1 mA: ±2.5%, ±5 counts (DC); ±1.5%, ±5 counts (40 Hz – 4 kHz); ±4.5%, ±5 counts (4 kHz − 40 kHz); 1 mA – 1000 mA: ±2.5%, ±5 counts (DC); ±1.5%, ±5 counts (40 Hz – 4 kHz); ±3.5%,±5 counts (4 kHz − 40 kHz)
Current range input resistance 0.1 mA: 1000 Ω; 1 mA: 100 Ω; 10 mA: 10.2 Ω; 100 mA: 1.2 Ω; 1000 mA: 0.3 Ω
Resistance 1 KΩ: ±0.5%, ±3 counts; 10 KΩ – 1 MΩ: ±0.5%, ±1 count; 10 MΩ: ±1%, ±1 count
     — Oscilloscope Section
Voltage ranges 5 mV/Div to – 100 V/Div, ±3%
Bandwidth (Voltage) DC – 1 MHz (at 10 mV/Div and below, 400 kHz)
Current ranges 5 µA/Div to 100 mA/Div, ±3%
Bandwidth (Current) DC – 200 kHz (5 µA/Div – 10 μA/Div); DC – 400 kHz (20 μA/Div – 200 mA/Div)
Input resistance 10 MΩ // 150 pF (5 mV/Div – 1 V/Div), 100 pF (2 V/Div to – 100 V/Div)
Rise time 875 ns (5 mV/Div – 10 mV/Div); 350 ns (20 mV/Div – 100 V/Div)
Sweep 500 ms/Div – 2 µs/Div, ±5% (magnified or unmagnified)
Batteries 2 × “D” NiCd cells
Operating time 3.5 hours typical at maximum intensity after full charge cycle
Charge time 16 h
Mains power 90 – 136 VAC. 48 – 62 Hz (Option 1: 180 – 250 VDC. or 180 – 250 VAC, 48 – 62 Hz)
Power consumption Less than 8 watts

Links

Internals

The 213 makes use of two Tek-made custom chips, the 155-0048-01 trigger sweep circuit, and the 155-0114-00 7-segment character generator in the DVM circuit. In addition, it includes some standard opamps (741, 324) and a 4-digit decimal counter (Mostek MK5007).

Pictures

Schematics