2246: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
(18 intermediate revisions by 6 users not shown)
Line 1: Line 1:
The Tektronix 2246 is a 100 MHz four channel* analog oscilloscope, with limited automatic measurement capability. It is part of a nearly identical family consisting of the [[2245]], 2246, [[2247]], and [[2252]].
{{Oscilloscope Sidebar |
title=Tektronix 2246 |
summary=100 MHz portable 4-channel scope |
image=USA Tektronix 2246A 0.jpg |
caption=Tektronix 2246 |
introduced=1988 |
discontinued=1995 |
manuals=
* [[Media:070-6083-00.pdf|Tektronix 2246 Operators Manual (PDF)]]
* [[Media:070-6556-01.pdf|Tektronix 2246A Operators Manual (PDF)]]
* [[Media:070-7061-00.pdf|Tektronix 2246 Operators Manual SN B100100 and above (PDF, OCR)]]
* [[Media:2246_service.pdf|Tektronix 2246 Service Manual (PDF, OCR)]]
<!-- * [[Media:070-7062-00.pdf|Tektronix 2246 Service Manual (PDF, OCR)]] -->
}}


Two channels are fully-functioned, and two are very limited, in both deflection factor and coupling.  
The '''Tektronix 2246''' is a 100 MHz four-channel analog oscilloscope.  Channels 1-2 are fully-functional, whereas 3-4 are limited in both deflection factor and coupling, as they are intended mainly for digital and trigger signals.


* [http://www.ko4bb.com/Manuals/Tektronix/Tektronix_-_2245A/Tektronix_2245_2246_Specification.pdf Tektronix 2245/2246 Specifications (PDF)]
The 2246 includes the same features of the 2245 plus STORE/RECALL SETUP up to different 20 front panel setups and can be arranged in sequence as required for specific applications. There are Labeled Volts Cursors with Ground-Referenced Readings and On-Screen Readouts; Hands-Off Voltmeter Measurements of DC Volts, +Peak and -Peak Volts, and P-P Volts; SmartCursors Integrate Voltage, Time, Frequency, and Phase Measurements, and are available in ALT and B Horizontal Modes.
* [http://www.ou.edu/aoi/images/Tektronix%202246%20Operators%20Manual.pdf Tektronix 2246 Operators Manual (PDF)]
 
* [http://w140.com/2246_service.pdf Tektronix 2246 Service Manual (PDF)]
{{BeginSpecs}}
{{Spec | Bandwidth | 100 MHz }}
{{Spec | Deflection| CH 1, CH 2: 2 mV/div to 5 V/div in 1-2-5 seq; CH 3, CH 4: 0.1 V/div and 0.5 V/div, all ±2%; BW Limit: 20 MHz ±15%  }}
{{Spec | Vertical Operating Modes | CH1,2,3,4, CH2 Invert, Add, Alt, Chop (625 kHz) }}
{{Spec | Input Impedance| 1 MΩ ±1.0% // 20 pF ±1 pF }}
{{Spec | Maximum Input Voltage| 400 V (DC + peak AC) or 800 V (p-p ac at ≤ 10 kHz) }}
{{Spec | Sweep Speeds| A Time Base: 0.5 s/div to 20 ns/div in 1-2-5 seq; B Time Base: 5 ms/div to 20 ns/div in 1-2-5 seq (×10 magnifier to 2 ns/div) }}
{{Spec | Trigger| DC, Noise Reject, HF Reject, LF Reject, AC, TV Line, TV Field }}
{{Spec | Trigger Modes| A Mode: Auto Level, Auto, Norm, TV Line, TV Field, Single Seq. B Mode: Runs After Delay, Auto Level, Norm, TV Line (From A Source) }}
{{Spec | Trigger Source A & B| Vert, CH1, 2, 3, 4, Line }}
{{Spec | Voltmeter| DC, +Peak, −Peak, PK-PK, Gated Volts, Smart Tracking Cursors: Volts, Gnd, Trigger Lvl }}
{{Spec | Cursors| Time, 1/Time, Delta Time, 1/Delta Time, Delta Phase, Volts }}
{{Spec | Interface| Ext Counter/Timer Base Input connector; Ext Z-Axis Input connector }}
{{Spec | Probes| Two [[P6109]] 100 MHz ×10 probes, [[BNC connector]] with a [[readout pin]] }}
{{Spec | Power| 100 W max, 90 − 250 V<sub>AC</sub>, 48 − 445 Hz }}
{{EndSpecs}}
 
==Models==
* 2246
* 2246 1Y
* 2246 2R
* 2246 Mod A
* 2246A
 
==See Also==
* [[067-0557-00]]
 
==Pictures==


<gallery>
<gallery>
File:USA Tektronix 2246A 0.jpg|2246A
USA Tektronix 2246A 0.jpg|2246A
Tek 2246 sine.jpg
Tek_2246_front2.jpg
Tek 2246 1.jpg
Tek 2246 2.jpg
Tek 2246 3.jpg
Tek 2246 4.jpg
Tek 2246 5.jpg
Tek 2246 6.jpg
2246(1).jpg
2246(2).jpg
2246(3).jpg
2246(4).jpg
2246A(1).jpg
2246A(2).jpg
</gallery>
</gallery>


[[Category:2246 series scopes]]
[[Category:2246 series scopes]]
[[Category:Image needed]]
[[Category:Specifications needed]]

Revision as of 23:23, 6 June 2019

{{{manufacturer}}} 
100 MHz portable 4-channel scope
Tektronix 2246

Produced from 1988 to 1995

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix 2246 is a 100 MHz four-channel analog oscilloscope. Channels 1-2 are fully-functional, whereas 3-4 are limited in both deflection factor and coupling, as they are intended mainly for digital and trigger signals.

The 2246 includes the same features of the 2245 plus STORE/RECALL SETUP up to different 20 front panel setups and can be arranged in sequence as required for specific applications. There are Labeled Volts Cursors with Ground-Referenced Readings and On-Screen Readouts; Hands-Off Voltmeter Measurements of DC Volts, +Peak and -Peak Volts, and P-P Volts; SmartCursors Integrate Voltage, Time, Frequency, and Phase Measurements, and are available in ALT and B Horizontal Modes.

Key Specifications

Bandwidth 100 MHz
Deflection CH 1, CH 2: 2 mV/div to 5 V/div in 1-2-5 seq; CH 3, CH 4: 0.1 V/div and 0.5 V/div, all ±2%; BW Limit: 20 MHz ±15%
Vertical Operating Modes CH1,2,3,4, CH2 Invert, Add, Alt, Chop (625 kHz)
Input Impedance 1 MΩ ±1.0% // 20 pF ±1 pF
Maximum Input Voltage 400 V (DC + peak AC) or 800 V (p-p ac at ≤ 10 kHz)
Sweep Speeds A Time Base: 0.5 s/div to 20 ns/div in 1-2-5 seq; B Time Base: 5 ms/div to 20 ns/div in 1-2-5 seq (×10 magnifier to 2 ns/div)
Trigger DC, Noise Reject, HF Reject, LF Reject, AC, TV Line, TV Field
Trigger Modes A Mode: Auto Level, Auto, Norm, TV Line, TV Field, Single Seq. B Mode: Runs After Delay, Auto Level, Norm, TV Line (From A Source)
Trigger Source A & B Vert, CH1, 2, 3, 4, Line
Voltmeter DC, +Peak, −Peak, PK-PK, Gated Volts, Smart Tracking Cursors: Volts, Gnd, Trigger Lvl
Cursors Time, 1/Time, Delta Time, 1/Delta Time, Delta Phase, Volts
Interface Ext Counter/Timer Base Input connector; Ext Z-Axis Input connector
Probes Two P6109 100 MHz ×10 probes, BNC connector with a readout pin
Power 100 W max, 90 − 250 VAC, 48 − 445 Hz

Models

  • 2246
  • 2246 1Y
  • 2246 2R
  • 2246 Mod A
  • 2246A

See Also

Pictures