The Tektronix 2246 is a 100 MHz four channel* analog oscilloscope, with limited automatic measurement capability. It is part of a nearly identical family consisting of the [[2245]], 2246, [[2247]], and [[2252]].
{{Oscilloscope Sidebar |
title=Tektronix 2246 |
summary=100 MHz portable 4-channel scope |
image=USA Tektronix 2246A 0.jpg |
caption=Tektronix 2246 |
introduced=1988 |
discontinued=1995 |
manuals=
* [[Media:070-6083-00.pdf|Tektronix 2246 Operators Manual (PDF)]]
* [[Media:070-6556-01.pdf|Tektronix 2246A Operators Manual (PDF)]]
* [[Media:070-7061-00.pdf|Tektronix 2246 Operators Manual SN B100100 and above (PDF, OCR)]]
* [[Media:2246_service.pdf|Tektronix 2246 Service Manual (PDF, OCR)]]
<!-- * [[Media:070-7062-00.pdf|Tektronix 2246 Service Manual (PDF, OCR)]] -->
}}


Two channels are fully-functioned, and two are very limited, in both deflection factor and coupling.  
The '''Tektronix 2246''' is a 100 MHz four-channel analog oscilloscope.  Channels 1-2 are fully-functional, whereas 3-4 are limited in both deflection factor and coupling, as they are intended mainly for digital and trigger signals.


* [http://www.ou.edu/aoi/images/Tektronix%202246%20Operators%20Manual.pdf Tektronix 2246 Operators Manual (PDF)]
The 2246 includes many of the same features of the 2245A and adds auto tracking SmartCursors which track the selected measurment, trigger level, or ground. There are Labeled Volts Cursors with Ground-Referenced Readings and On-Screen Readouts; Hands-Off Voltmeter Measurements of DC Volts, +Peak and -Peak Volts, and P-P Volts; SmartCursors Integrate Voltage, Time, Frequency, and Phase Measurements, and are available in ALT and B Horizontal Modes.
* [http://w140.com/2246_service.pdf Tektronix 2246 Service Manual (PDF)]
 
{{BeginSpecs}}
{{Spec | Bandwidth | 100 MHz }}
{{Spec | Deflection| CH 1, CH 2: 2 mV/div to 5 V/div in 1-2-5 seq; CH 3, CH 4: 0.1 V/div and 0.5 V/div, all ±2%; BW Limit: 20 MHz ±15% }}
{{Spec | Vertical Operating Modes | CH1,2,3,4, CH2 Invert, Add, Alt, Chop (625 kHz) }}
{{Spec | Input Impedance| 1 MΩ ±1.0% // 20 pF ±1 pF }}
{{Spec | Maximum Input Voltage| 400 V (DC + peak AC) or 800 V (p-p ac at ≤ 10 kHz) }}
{{Spec | Sweep Speeds| A Time Base: 0.5 s/div to 20 ns/div in 1-2-5 seq; B Time Base: 5 ms/div to 20 ns/div in 1-2-5 seq (×10 magnifier to 2 ns/div) }}
{{Spec | Trigger| DC, Noise Reject, HF Reject, LF Reject, AC, TV Line, TV Field }}
{{Spec | Trigger Modes| A Mode: Auto Level, Auto, Norm, TV Line, TV Field, Single Seq. B Mode: Runs After Delay, Auto Level, Norm, TV Line (From A Source) }}
{{Spec | Trigger Source A & B| Vert, CH1, 2, 3, 4, Line }}
{{Spec | Voltmeter| DC, +Peak, −Peak, PK-PK, Gated Volts, Smart Tracking Cursors: Volts, Gnd, Trigger Lvl }}
{{Spec | Cursors| Time, 1/Time, Delta Time, 1/Delta Time, Delta Phase, Volts }}
{{Spec | Interface| Ext Counter/Timer Base Input connector; Ext Z-Axis Input connector }}
{{Spec | Probes| Two [[P6109]] 100 MHz ×10 probes, [[BNC connector]] with a [[readout pin]] }}
{{Spec | Power| 100 W max, 90 − 250 V<sub>AC</sub>, 48 − 445 Hz }}
{{EndSpecs}}
 
==Models==
* 2246
* 2246 1Y
* 2246 2R
* 2246 Mod A
* 2246A
 
==See Also==
* [[067-0557-00]]
 
==Pictures==


<gallery>
<gallery>
File:USA Tektronix 2246A 0.jpg|2246A
USA Tektronix 2246A 0.jpg|2246A
Tek 2246 sine.jpg
Tek_2246_front2.jpg
Tek 2246 1.jpg
Tek 2246 2.jpg
Tek 2246 3.jpg
Tek 2246 4.jpg
Tek 2246 5.jpg
Tek 2246 6.jpg
2246(1).jpg
2246(2).jpg
2246(3).jpg
2246(4).jpg
2246A(1).jpg
2246A(2).jpg
</gallery>
</gallery>


[[Category:2246 series scopes]]
[[Category:2246 series scopes]]
[[Category:Image needed]]
[[Category:Specifications needed]]

Revision as of 13:55, 28 September 2019

{{{manufacturer}}} 
100 MHz portable 4-channel scope
Tektronix 2246

Produced from 1988 to 1995

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix 2246 is a 100 MHz four-channel analog oscilloscope. Channels 1-2 are fully-functional, whereas 3-4 are limited in both deflection factor and coupling, as they are intended mainly for digital and trigger signals.

The 2246 includes many of the same features of the 2245A and adds auto tracking SmartCursors which track the selected measurment, trigger level, or ground. There are Labeled Volts Cursors with Ground-Referenced Readings and On-Screen Readouts; Hands-Off Voltmeter Measurements of DC Volts, +Peak and -Peak Volts, and P-P Volts; SmartCursors Integrate Voltage, Time, Frequency, and Phase Measurements, and are available in ALT and B Horizontal Modes.

Key Specifications

Bandwidth 100 MHz
Deflection CH 1, CH 2: 2 mV/div to 5 V/div in 1-2-5 seq; CH 3, CH 4: 0.1 V/div and 0.5 V/div, all ±2%; BW Limit: 20 MHz ±15%
Vertical Operating Modes CH1,2,3,4, CH2 Invert, Add, Alt, Chop (625 kHz)
Input Impedance 1 MΩ ±1.0% // 20 pF ±1 pF
Maximum Input Voltage 400 V (DC + peak AC) or 800 V (p-p ac at ≤ 10 kHz)
Sweep Speeds A Time Base: 0.5 s/div to 20 ns/div in 1-2-5 seq; B Time Base: 5 ms/div to 20 ns/div in 1-2-5 seq (×10 magnifier to 2 ns/div)
Trigger DC, Noise Reject, HF Reject, LF Reject, AC, TV Line, TV Field
Trigger Modes A Mode: Auto Level, Auto, Norm, TV Line, TV Field, Single Seq. B Mode: Runs After Delay, Auto Level, Norm, TV Line (From A Source)
Trigger Source A & B Vert, CH1, 2, 3, 4, Line
Voltmeter DC, +Peak, −Peak, PK-PK, Gated Volts, Smart Tracking Cursors: Volts, Gnd, Trigger Lvl
Cursors Time, 1/Time, Delta Time, 1/Delta Time, Delta Phase, Volts
Interface Ext Counter/Timer Base Input connector; Ext Z-Axis Input connector
Probes Two P6109 100 MHz ×10 probes, BNC connector with a readout pin
Power 100 W max, 90 − 250 VAC, 48 − 445 Hz