2440: Difference between revisions
No edit summary |
m (→Internals) |
||
(35 intermediate revisions by 7 users not shown) | |||
Line 3: | Line 3: | ||
image=2440_1.jpg | | image=2440_1.jpg | | ||
caption=Tektronix 2440 | | caption=Tektronix 2440 | | ||
introduced=1988 | | introduced=1988 | | ||
discontinued=(?) | | discontinued=(?) | | ||
summary=300 MHz, 500 MS/s 2-ch digital scope | | summary=300 MHz, 500 MS/s 2-ch digital scope | | ||
manuals= | manuals= | ||
* [http://w140.com/tek_2440_service.pdf Tektronix 2440 Manual (complete, B014064 and below) (PDF)] | * [http://w140.com/tek_2440_service.pdf Tektronix 2440 Manual (complete, B014064 and below) (PDF, OCR)] | ||
* [http://w140.com/tek_2440_programmer_man.pdf Tektronix 2440 Programmer Manual (PDF)] | * [http://w140.com/tek_2440_programmer_man.pdf Tektronix 2440 Programmer Manual (PDF, OCR)] | ||
* [http://w140.com/tek_2440.pdf Tektronix 2440 Manual (without schematics) (PDF)] | * [http://w140.com/tek_2440.pdf Tektronix 2440 Manual (without schematics) (PDF)] | ||
* [[Media: | * [[Media:2430A-2432A-2440-catalog.pdf|2430A/2432A/2440 catalog page (PDF, OCR)]] | ||
}} | }} | ||
The '''Tektronix 2440''' is a two-channel 300 MHz digital sampling oscilloscope from the late 1980s. | The '''Tektronix 2440''' is a two-channel 300 MHz, 500 MS/s digital sampling oscilloscope from the late 1980s. | ||
It uses CCDs (essentially, analog shift registers) to store input samples at high speed and a single 8 bit flash A/D converter to digitize the time-multiplexed CCD output signals at 4 MS/s. | |||
<blockquote> | |||
'''WARNING:'''<br /> | |||
Operation of the 2440 (and 2432 and 2430): A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling. | |||
</blockquote> | |||
{{ | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 300 MHz (Limit: 20, 100, Full) }} | |||
{{Spec | Sampling rate | 500 MSa/s each channel with simultaneous acquisition }} | |||
{{Spec | Deflection | 2 mV/div to 5 V/div in 1-2-5 sequence }} | |||
{{Spec | Auto Scale Factor | On-Screen Readout indicates probe tip deflection factors for ×1, ×10, ×100 and ×1000 probes }} | |||
{{Spec | Input Impedance| 1 MΩ // 15 pF }} | |||
{{Spec | Sweep Speeds | 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)}} | |||
{{Spec | Auto Measure| Simultaneously measures up to four parameters on one or more displayed waveforms, updated at 3 Hz intervals or display a snapshot of 20 parameters of waveform target }} | |||
{{Spec | Acquisition Modes| Normal, Envelope (glitch capture), Average }} | |||
{{Spec | Display Modes| CH1, CH2, invert, add, multiply, X-Y }} | |||
{{Spec | Cursors | Volts, Time, Volts At Time, 1/Time, Slope }} | |||
{{Spec | Functions | A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more }} | |||
{{Spec | Interface | GPIB }} | |||
{{Spec | Probes | Two passive [[P6137]] 400 MHz ×10 voltage probes, 1.3 m }} | |||
{{Spec | Power | 90 to 132 V<sub>AC</sub> or 80 to 250 V<sub>AC</sub>, 48 to 440 Hz; 160 W }} | |||
{{Spec | Features | | |||
* Autoprobe Function With [[P6137]] Probe | |||
* 300 MHz X-Y bandwidth at probe tip | |||
* Automatic measurements | |||
* extensive triggering capabilities | |||
* Printer/Plotter Output | |||
* On-screen HELP text describing every front-panel control | |||
}} | |||
{{Spec | Options | | |||
* 03 - Word Recognizer ([[P6407]]) | |||
* 05 - Video Waveform Measurement System | |||
* 11 - Two [[LEMO S-series connector|probe-power connectors]] on the rear panel | |||
}} | |||
{{EndSpecs}} | |||
==Links== | |||
* [https://hohlerde.org/rauch/en/elektronik/geraete/tek2440/ Tektronix 2440 internals & repair @ hohlerde.org] | |||
==Internals== | |||
The 2440 employs several processors − an MC68B09 main CPU controls the instrument, a custom 16-bit waveform processor performs signal computations, and an MC6805 microcontroller handles the front panel interface. The GPIB Interface is implemented with a TMS9914 controller. | |||
The power supply consists of a buck-type pre-regulator followed by a push-pull inverter and linear post-regulators (except for the +5 V digital supply rail). | |||
CRT is a [[154-0850-01]]. | |||
==Pictures== | |||
<gallery> | |||
Tek 2440 1.jpg | |||
Tek 2440 2.jpg | |||
Tek 2440 3.jpg | |||
Tek 2440 4.jpg | |||
Tek 2440 5.jpg | |||
Tek 2440 rear2.jpg | |||
2440 1A.jpg | |||
2440 1B.jpg | |||
</gallery> | |||
[[Category: | [[Category:2400 series scopes]] | ||
[[Category:Digital storage scopes]] | [[Category:Digital storage scopes]] | ||
[[Category:GPIB interface]] | [[Category:GPIB interface]] |
Revision as of 13:34, 12 March 2019
The Tektronix 2440 is a two-channel 300 MHz, 500 MS/s digital sampling oscilloscope from the late 1980s.
It uses CCDs (essentially, analog shift registers) to store input samples at high speed and a single 8 bit flash A/D converter to digitize the time-multiplexed CCD output signals at 4 MS/s.
WARNING:
Operation of the 2440 (and 2432 and 2430): A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.
Key Specifications
Bandwidth | 300 MHz (Limit: 20, 100, Full) |
---|---|
Sampling rate | 500 MSa/s each channel with simultaneous acquisition |
Deflection | 2 mV/div to 5 V/div in 1-2-5 sequence |
Auto Scale Factor | On-Screen Readout indicates probe tip deflection factors for ×1, ×10, ×100 and ×1000 probes |
Input Impedance | 1 MΩ // 15 pF |
Sweep Speeds | 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B) |
Auto Measure | Simultaneously measures up to four parameters on one or more displayed waveforms, updated at 3 Hz intervals or display a snapshot of 20 parameters of waveform target |
Acquisition Modes | Normal, Envelope (glitch capture), Average |
Display Modes | CH1, CH2, invert, add, multiply, X-Y |
Cursors | Volts, Time, Volts At Time, 1/Time, Slope |
Functions | A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more |
Interface | GPIB |
Probes | Two passive P6137 400 MHz ×10 voltage probes, 1.3 m |
Power | 90 to 132 VAC or 80 to 250 VAC, 48 to 440 Hz; 160 W |
Features |
|
Options |
|
Links
Internals
The 2440 employs several processors − an MC68B09 main CPU controls the instrument, a custom 16-bit waveform processor performs signal computations, and an MC6805 microcontroller handles the front panel interface. The GPIB Interface is implemented with a TMS9914 controller.
The power supply consists of a buck-type pre-regulator followed by a push-pull inverter and linear post-regulators (except for the +5 V digital supply rail).
CRT is a 154-0850-01.