308: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(manual)
Line 1: Line 1:
[[File:308-timing.jpg|300px|thumb|right|Tektronix 308]]
{{Oscilloscope Sidebar |
title=Sony/Tektronix 308 |
summary=20 MHz 8-ch Logic Analyzer |
image=308-timing.jpg |
caption=Sony/Tektronix 308 |
introduced=1980|
discontinued=1986|
manuals=
* [[Media:070-2663-00.pdf | Tek 308 Operator's Manual (PDF, 3MB)]]
* [[Media:070-2662-00.pdf | Tek 308 Service manual (PDF, OCR, 13MB)]]
}}
The '''Sony/Tektronix 308''' is a portable 8-channel, 20 MHz "data analyzer" (logic analyzer) with parallel timing, parallel state, serial (up to 9600 bps) and signature analysis modes.
The '''Sony/Tektronix 308''' is a portable 8-channel, 20 MHz "data analyzer" (logic analyzer) with parallel timing, parallel state, serial (up to 9600 bps) and signature analysis modes.


The 308 uses two probes, the standard [[P6451]] 8-channel + clock data acquisition probe, and the optional 16-channel [[P6406]] word recognizer probe. Both use  [[012-0747-00]] cable harnesses to attach to the data source.
The 308 uses two probes, the standard [[P6451]] 8-channel + clock data acquisition probe, and the optional 16-channel [[P6406]] word recognizer probe. Both use  [[012-0747-00]] cable harnesses to attach to the data source.
==Manuals==
* [http://w140.com/tek_308_instructions.pdf Tektronix 308 Operator's Manual (PDF)]
* Service manual / schematics needed [[Category:Manual needed]]


{{BeginSpecs}}
{{BeginSpecs}}

Revision as of 11:02, 21 June 2017

{{{manufacturer}}} 
20 MHz 8-ch Logic Analyzer
Sony/Tektronix 308

Produced from 1980 to 1986

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Sony/Tektronix 308 is a portable 8-channel, 20 MHz "data analyzer" (logic analyzer) with parallel timing, parallel state, serial (up to 9600 bps) and signature analysis modes.

The 308 uses two probes, the standard P6451 8-channel + clock data acquisition probe, and the optional 16-channel P6406 word recognizer probe. Both use 012-0747-00 cable harnesses to attach to the data source.

Key Specifications

     — Inputs
Data Eight data channels + 1 clock channel (P6451 probe), impedance 1 MΩ // 5 pF, max. ±40 V nondestructive, logic threshold fixed 1.4 V (TTL) or variable from -12 V to +12 V
Word recognizer Sixteen TTL inputs (+40/-400 μA max.), max. +15/-1 V
Serial BNC connector, 1 MΩ // 40 pF, max. ±250 V on BNC; used with P6107 probe, 10 MΩ // 13 pF, max. ±500 V
Qualifier BNC connector, 10 kΩ, max. +10/-5 V
     — Acquisition
Clock 50 ns to 200 ms per sample (1-2-5 sequence) or external down to 50 ns
Timing Data setup time min. 25 ns, hold time min. 0 ns
Memory 2 × 252 eight-bit words (acquisition + reference)
Trigger mode PRE (trigger at memory location 240) or POST (location 13)
Trigger delay 0-65535 clock periods
Serial data 5, 6, 7 or 8 bits per character, asynchronous (50, 75, 110, 134.5, 150, 200, 300, 600, 1200, 1900, 2400, 4800 or 9600 bits/s or external up to 9600 bits/s) or synchronous up to 9600 bits/s
     — Display
CRT 6.8 cm × 5.4 cm, P4 phosphor (white)
     — General
Power 90-132 V or 180-250 V, 48-440 Hz
Weight 3.7 kg (8.16 lb)

Links

Internals

The 308 is built around an Intel 8085A microprocessor. The display is a magnetically deflected raster-scan CRT. The only Tek-specific IC in the 308 is a 155-0067-02 SMPS controller.

Pictures