3B2

From TekWiki
Revision as of 12:32, 14 August 2021 by Peter (talk | contribs) (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=)
Jump to navigation Jump to search
Tektronix 3B2
Delaying timebase
Tektronix 3B2 front

Compatible with 560-series scopes

Produced from 1963 to 1974

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix Type 3B2 is a delaying timebase introduced in 1963 for 560-series scopes except the 560 and 565. It can trigger on signals up to 30 MHz.

The 3B2 has a 6CW4 Nuvistor triode cathode-follower buffer amplifier at the trigger input, followed by a differential trigger amplifier made of a pair of PNP transistors, with a 2 mA tunnel diode acting as the actual trigger.

The 3B2 has a 1 MHz crystal oscillator and a counter made of discrete transistors. It generates output pulses that enable it to communicate with a digital unit such as the 6R1 or 6R1A.

The 3B2 uses a 6AL5 tube as the disconnect diode for the sweep.

Specifications

please add

Pictures