The Tektronix Type 3B4 is a timebase plug-in for 560-series scopes.  It was introduced in 1964.
The Tektronix Type 3B4 is a timebase plug-in for [[560-series scopes]].  It was introduced in 1964.
It was intended primarily for use
It was intended primarily for use
with the 561A, but works fine in other 560-series scopes.  The 3B4 is unusual in having an explicit
with the 561A, but works fine in other 560-series scopes.  The 3B4 is unusual in having an explicit
"FREE RUN" mode.  In the triggered modes, the tunnel diode-based triggering is rated to work to 20MHz.   
"FREE RUN" mode.   
In the triggered modes, the [[tunnel diodes|tunnel diode]]-based triggering is rated to work to 20MHz.   
The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10MHz, so 20MHz is adequate.
The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10MHz, so 20MHz is adequate.
Triggering is done with a TD3A 4.7mA tunnel diode.  The trigger input is amplified and buffered by a
Triggering is done with a [[TD3A]] 4.7mA tunnel diode.  The trigger input is amplified and buffered by a
6DJ8-based differential amplifier driving a common-emitter 2N964 germanium PNP transistor whose  
[[6DJ8]]-based differential amplifier driving a common-emitter [[2N964]] germanium PNP transistor whose  
collector current switches the tunnel diode.
collector current switches the tunnel diode.
 