3S7: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
(2 intermediate revisions by 2 users not shown)
Line 8: Line 8:
discontinued=1973 |
discontinued=1973 |
manuals=
manuals=
* [http://w140.com/tek_3s7_3t7.pdf Tektronix 3S7/3T7 Manual (PDF)]
* [http://w140.com/tek_3s7_3t7_with_index.pdf Tektronix 3S7/3T7 Manual (PDF)]
}}
}}
The '''Tektronix Type 3S7''' is a [[sampling_oscilloscope|sampling]] plug-in  
The '''Tektronix Type 3S7''' is a [[sampling_oscilloscope|sampling]] plug-in  
Line 15: Line 15:
Used with the [[3T7]], a TDR system is formed.  The 3S7/3T7 are seen on the front cover of the document
Used with the [[3T7]], a TDR system is formed.  The 3S7/3T7 are seen on the front cover of the document
[http://slack.com/TE/TekConcepts/TekTDRMeas.pdf Tektronix TDR Measurement Concepts].   
[http://slack.com/TE/TekConcepts/TekTDRMeas.pdf Tektronix TDR Measurement Concepts].   
Like the [[1S2]], the connectors on the 3S7/3T7 are 50 Ω [[Connectors#GR-874|GR-874]].
Like the [[1S2]], the connectors on the 3S7/3T7 are 50 Ω [[GR-874 connector]]s.
A short coaxial cable carries the pulse from the front panel output of the
A short coaxial cable carries the pulse from the front panel output of the
3T7 to the front panel input of the 3S7, where it passes through the  
3T7 to the front panel input of the 3S7, where it passes through the  
sampling gate and out to the cable or network under test.
sampling gate and out to the cable or network under test.
The interface between the GR-874 connector and the printed circuit board is described in US Patent 3,426,311.


==Specifications==
==Specifications==

Revision as of 13:51, 5 November 2017

Template:Plugin Sidebar 2 The Tektronix Type 3S7 is a sampling plug-in for 560-series scopes such as the 561 and 564. The 3S7 was introduced in 1971.

Used with the 3T7, a TDR system is formed. The 3S7/3T7 are seen on the front cover of the document Tektronix TDR Measurement Concepts. Like the 1S2, the connectors on the 3S7/3T7 are 50 Ω GR-874 connectors. A short coaxial cable carries the pulse from the front panel output of the 3T7 to the front panel input of the 3S7, where it passes through the sampling gate and out to the cable or network under test.

The interface between the GR-874 connector and the printed circuit board is described in US Patent 3,426,311.

Specifications

please add

Pictures