'''''Note:''' The [[465M|'''Tektronix 465M''' scope has its own page]]. | |||
{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | | ||
title=Tektronix 465 | | title=Tektronix 465 | | ||
Line 7: | Line 8: | ||
discontinued=1983 | | discontinued=1983 | | ||
manuals= | manuals= | ||
* [ | ====465==== | ||
* [[Media:070-2038-00.pdf|465 + DM44 Operator]] (OCR PDF, 4M) | |||
* [[Media:Tektronix_070-2038-00_465_Oscilloscope_and_DM44_Digital_Multimeter_Operators_Instruction_Manual_First_Printing_July_1976.pdf | 465 + DM44 Operator]] (2) | |||
* [[Media:070-1330-00.pdf|465 Service]] (OCR PDF, 3M) | |||
* [[Media:070-1330-00_465Service.pdf | 465 Service ]] (PDF) / [[Media:Tektronix_070-1330-00_465_Oscilloscope_Service_Instruction_Manual.tif | TIF version]] (non OCR) | |||
* [[Media:070-1861-00.pdf|465 Service B250000+]] (OCR PDF, 44M) | |||
* [[Media:070-1861-00_C.pdf|465 Service B250000+]] (Color OCR PDF, 58M) | |||
* [[Media:070-2191-00.pdf|465 Option 5 Supplement]] (PDF) | |||
====465B==== | |||
* [[Media:070-2756-00.pdf|465B + DM44 Operator 09/1981, with Option 05]] (OCR PDF) | |||
* [http://w140.com/465B_svc.pdf Tektronix 465B Manual (200MB, PDF)] | * [http://w140.com/465B_svc.pdf Tektronix 465B Manual (200MB, PDF)] | ||
* [http://w140.com/465b_trig2.pdf Tektronix 465B Trigger Generator Schematic (PDF)] | * [http://w140.com/465b_trig2.pdf Tektronix 465B Trigger Generator Schematic (PDF)] | ||
* [[Media:465b_schematic.pdf|Tektronix 465B Trigger Generator Schematic (PDF, OCR, bad-OCR)]] | |||
* [[Media: | * [[Media:050-1558-00.pdf|Modification: U3165 Replacement]] | ||
* [[Media: | |||
<small> | <small> | ||
'''Modifications''' | '''Modifications''' | ||
Line 28: | Line 32: | ||
* [http://hakanh.com/dl/docs/kitinstructions/050-1627-00.pdf 050-1627-00]: S1150 (Time/cm switch) replacement | * [http://hakanh.com/dl/docs/kitinstructions/050-1627-00.pdf 050-1627-00]: S1150 (Time/cm switch) replacement | ||
</small> | </small> | ||
====History==== | |||
* [[Media:Tek 465 and 475 marketing sales release.pdf|Tektronix 465 and 475 Marketing Sales Release (PDF)]] | |||
}} | }} | ||
Line 33: | Line 41: | ||
The 465 was very popular and Tek made them for quite a few years. | The 465 was very popular and Tek made them for quite a few years. | ||
It is all solid-state except for the CRT. It was introduced in November 1972. | It is all solid-state except for the CRT. It was introduced in November 1972. | ||
[[Bill Turner|There was no 465A]] but a 465B (int. 1980) with the same base specs but improved performance. | [[Bill Turner|There was no 465A]] but a 465B (int. 1980) with the same base specs but improved performance. | ||
The [[475]] is a 200 MHz sister model. | The [[475]] is a 200 MHz sister model. See also [[465M]]. | ||
The optional [[DM44]] multimeter attaches to the top of the instrument. | The optional [[DM44]] multimeter attaches to the top of the instrument. | ||
[[Bill Turner]] worked as a calibration technician for the 465 oscilloscope group. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | DC to 100 MHz on CH1 & CH2 for | {{Spec | Bandwidth | DC to 100 MHz on CH1 & CH2 for −15°C to +40°C and DC to 85 MHz from +40°C to +55°C}} | ||
{{Spec | Rise time | 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C}}} | {{Spec | Rise time | 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C}}} | ||
{{Spec | Input Impedance | 1 MΩ ±2% // 20 pF }} | {{Spec | Input Impedance | 1 MΩ ±2% // 20 pF }} | ||
{{Spec | | {{Spec | Input Voltage | max. 500 V DC (250 V<sub>DC</sub> when DC coupled) + Peak AC or 500 V<sub>p-p</sub> AC at < 1 kHz }} | ||
{{Spec | Trigger Coupling | {{Spec | Trigger Coupling | DC, AC, LF Reject, HF Reject}} | ||
{{Spec | | {{Spec | Channel Isolation | 100:1 at 25 MHz }} | ||
{{Spec | Z Axis Input | 5 V<sub>p-p</sub> signal causes noticeable modulation at normal intensity | {{Spec | Z Axis Input | DC to 50 MHz; 5 V<sub>p-p</sub> signal causes noticeable modulation at normal intensity }} | ||
{{Spec | Output Signals | CH1 Vertical, A & B +Gate}} | {{Spec | Output Signals | CH1 Vertical, A & B +Gate}} | ||
{{Spec | Calibrator | {{Spec | Calibrator | ~1 kHz, 300 mV, square wave}} | ||
{{Spec | CRT | {{Spec | CRT | [[154-0676-10]] tube, P31 [[phosphor]], 18.5 kV acceleration, 8 cm × 10 cm graticule }} | ||
{{Spec | Line Voltage | 110/115/120/220/230/240 V<sub>AC</sub> ±10%, selected via primary voltage selector and regulating range selector assembly, 48 Hz to 440 Hz }} | |||
{{Spec | Line Voltage | 110/115/120/220/240 V<sub>AC</sub> ±10%, selected via primary voltage selector and regulating | |||
{{Spec | Power Consumption | 75 W @ 115 V<sub>AC</sub> / 60 Hz}} | {{Spec | Power Consumption | 75 W @ 115 V<sub>AC</sub> / 60 Hz}} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Internals== | ==Internals== | ||
The 465 uses tunnel diodes with Tek part number 152-0125-00, | The 465 uses tunnel diodes with Tek part number 152-0125-00, | ||
which are equivalent to [[TD3A]], and [[155-0032-00]] chips (their -01 grade) as trigger amplifiers. | which are equivalent to [[TD3A]], and [[155-0032-00]] chips (their -01 grade) as trigger amplifiers. | ||
==Links== | ==Links== | ||
Line 76: | Line 78: | ||
* [http://dangerousprototypes.com/2012/03/19/tektronix-465-oscilloscope-teardown/ Tek 465 "teardown"] | * [http://dangerousprototypes.com/2012/03/19/tektronix-465-oscilloscope-teardown/ Tek 465 "teardown"] | ||
* [https://groups.io/g/TekScopes/files/Replacing%20Electrolytic%20Filter%20Capacitors%20in%20a%20Tektronix%20465.pdf Replacing Electrolytic Filter Capacitors in a Tektronix 465] | * [https://groups.io/g/TekScopes/files/Replacing%20Electrolytic%20Filter%20Capacitors%20in%20a%20Tektronix%20465.pdf Replacing Electrolytic Filter Capacitors in a Tektronix 465] | ||
* [[T4650|Tektronix T4650 CRT]] | |||
* [[050-0674-00|Handle Replacement Modification Kit]] | |||
==Common Problems== | |||
* See [[465/Repairs]] | |||
==Pictures== | ==Pictures== | ||
===465=== | ===465=== | ||
<gallery> | <gallery> | ||
Tek-465-front.jpg | |||
Tek-465-back.jpg | |||
Tek 465 trace.jpg | Tek 465 trace.jpg | ||
Tek 465 front2.jpg | Tek 465 front2.jpg | ||
Tek 465 front right.jpg | Tek 465 front right.jpg | ||
Tek-465-int1.jpg | |||
Tek-465-int2.jpg | |||
Tek-465-int3.jpg | |||
Tek-465-int4.jpg | |||
</gallery> | </gallery> | ||
===465B=== | ===465B=== |
Revision as of 06:14, 2 November 2019
Note: The Tektronix 465M scope has its own page.
The Tektronix 465 is a portable 100 MHz dual-trace oscilloscope with dual time-bases.
The 465 was very popular and Tek made them for quite a few years.
It is all solid-state except for the CRT. It was introduced in November 1972.
There was no 465A but a 465B (int. 1980) with the same base specs but improved performance. The 475 is a 200 MHz sister model. See also 465M.
The optional DM44 multimeter attaches to the top of the instrument.
Bill Turner worked as a calibration technician for the 465 oscilloscope group.
Key Specifications
}Bandwidth | DC to 100 MHz on CH1 & CH2 for −15°C to +40°C and DC to 85 MHz from +40°C to +55°C |
---|---|
Rise time | 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C |
Input Impedance | 1 MΩ ±2% // 20 pF |
Input Voltage | max. 500 V DC (250 VDC when DC coupled) + Peak AC or 500 Vp-p AC at < 1 kHz |
Trigger Coupling | DC, AC, LF Reject, HF Reject |
Channel Isolation | 100:1 at 25 MHz |
Z Axis Input | DC to 50 MHz; 5 Vp-p signal causes noticeable modulation at normal intensity |
Output Signals | CH1 Vertical, A & B +Gate |
Calibrator | ~1 kHz, 300 mV, square wave |
CRT | 154-0676-10 tube, P31 phosphor, 18.5 kV acceleration, 8 cm × 10 cm graticule |
Line Voltage | 110/115/120/220/230/240 VAC ±10%, selected via primary voltage selector and regulating range selector assembly, 48 Hz to 440 Hz |
Power Consumption | 75 W @ 115 VAC / 60 Hz |
Internals
The 465 uses tunnel diodes with Tek part number 152-0125-00, which are equivalent to TD3A, and 155-0032-00 chips (their -01 grade) as trigger amplifiers.
Links
- Rajesh's Tek 465 Repair
- The New Look in Portables, in Tekscope Vol. 4 No. 5, 1972
- Jim Williams repairs Tom Osborne's Tektronix 465B oscilloscope (YouTube)
- Another successful 465 repair, shorted tantalum (YouTube)
- Repairing a 465 (power supply, z axis amplifier, vertical pre amplifier issues) - nice internal photos
- Tek 465 page @ amplifier.cd
- 465B differences
- Tek 465 "teardown"
- Replacing Electrolytic Filter Capacitors in a Tektronix 465
- Tektronix T4650 CRT
- Handle Replacement Modification Kit
Common Problems
- See 465/Repairs