475: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
Line 34: Line 34:
It is all solid-state except for the CRT.  
It is all solid-state except for the CRT.  
It was introduced in November 1972.
It was introduced in November 1972.
Military variant is called OS-261 C(v)1/0, which has DC/DC converter  (12/24V input) on board.


A revised version, the 475A, has 250 MHz bandwidth and a maximum vertical sensitivity of 5 mV/Div.
A revised version, the 475A, has 250 MHz bandwidth and a maximum vertical sensitivity of 5 mV/Div.
Line 83: Line 85:
Tek_475A_Time-Freq.jpg | 475A Time/Frequency Measurement with [[DM44]], HP Frequency Counter used for Verifying [[DM44]] Output.
Tek_475A_Time-Freq.jpg | 475A Time/Frequency Measurement with [[DM44]], HP Frequency Counter used for Verifying [[DM44]] Output.
Tek 475a rear.jpg|475A rear
Tek 475a rear.jpg|475A rear
Tek_OS_261_rear.jpg | 475 (OS-261 C) rear, with DC-Input
475A_A9-Interface_board.jpg | 475A A9 Interface Board
475A_A9-Interface_board.jpg | 475A A9 Interface Board
475A_A6_Fan_motor.jpg |475A A6 & Fan Motor  
475A_A6_Fan_motor.jpg |475A A6 & Fan Motor  

Revision as of 05:56, 23 November 2019

Manuals – Specifications – Links – Pictures

The Tektronix 475 is a portable dual-trace oscilloscope with dual time-bases similar to the 465, but with 200 MHz bandwidth and a maximum vertical sensitivity of 2 mV/Div. It is all solid-state except for the CRT. It was introduced in November 1972.

Military variant is called OS-261 C(v)1/0, which has DC/DC converter (12/24V input) on board.

A revised version, the 475A, has 250 MHz bandwidth and a maximum vertical sensitivity of 5 mV/Div. The 1106 is a battery pack for the 475.

The optional DM44 multimeter attaches to the top of the instrument.

Key Specifications

Bandwidth 200 MHz (475), AC cutoff 10 Hz, switchable BW limit 20 MHz
Rise time 1.75  ns (475)
Deflection 2 mV/Div to 5 V/Div, 1-2-5
Cascaded mode 400 μV/Div, 50 MHz with CH1 input connected to CH2 VERT SIG OUT
Time base 10 ns/Div to 500 ms/Div, 1-2-5, and ×10 magnifier
Input impedance 1 MΩ // 20 pF
Triggering 0.3 Div (int) or 50 mV (ext) to 40 MHz, increasing to 1.5 Div/250 mV at 200 MHz; AC coupling >60 Hz; LF REJ >50 kHz, HF REJ <50 kHz
X bandwidth 3 MHz
Z axis input 5 Vp-p, 50 MHz
Calibrator 1 kHz, 30 mA / 300 mV square wave
Outputs CH2 Vert Signal Out, 20 mV/Div into 1 MΩ or 10 mV/Div into 50 Ω; A and B +GATE OUT, +5 V; Probe power jack
CRT 8 × 10 cm², P31 phosphor (P11 opt.)
Power 110, 115, 120, 220, 230 or 240  VAC ±10%, 48-440 Hz, max. 100 W

Internals

The 475 uses a number of Tek-made integrated circuits, including the 155-0032-01 input preamplifier, 155-0085-00 input amplifier, 155-0078-00 vertical amplifier, 155-0091-00 channel switch, 155-0082-00 vertical output amplifier, and 155-0049-00 sweep control.

Links

Common Problems

Pictures