5116: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 11: Line 11:
* [http://w140.com/Oscilloscopes_in_color_tek_5116.pdf Radio Electronics Article on Tek 5116 (PDF)]
* [http://w140.com/Oscilloscopes_in_color_tek_5116.pdf Radio Electronics Article on Tek 5116 (PDF)]
}}
}}
The '''Tektronix 5116''' is a single beam mainframe that has a colour LCD shutter in front of the CRT.
The '''Tektronix 5116''' is a single beam mainframe that has a two-colour LCD shutter in front of a CRT with P4 (white) [[phosphor]].


The color shutter works only with the [[5D10|5D10 digitizer plug-in]].  
The color shutter works only with the [[5D10|5D10 digitizer plug-in]]. The 5116 manual says "The 5116 will not produce color  
The 5116 manual says "The 5116 will not produce color signals if the 5D10 Waveform Digitizer does not have a serial number of B020100 or greater."
signals if the 5D10 Waveform Digitizer does not have a serial number of B020100 or greater."
 
The shutter consists of one red and one green polarizer/LCD combinations the size of the visible screen.
The 5D10 in turn enables the red shutter, draws the red parts of display, turns on the green shutter in addition, draws
the yellow (red+green) parts of the display, then turns off the red shutter, and draws the green parts of the display,
at a rate of about 20 Hz.  The slow multiplexing rate can lead to color artifacts becoming visible when the observer moves.


In contrast with what is mentioned sometimes, the 5116 does '''not''' provide alphanumeric readout. The 5D10 takes care of this.
In contrast with what is mentioned sometimes, the 5116 does '''not''' provide alphanumeric readout. The 5D10 takes care of this.

Revision as of 03:23, 15 June 2018

{{{manufacturer}}} 
Color-display scope mainframe
Tektronix 5116

Produced from 1984 to 1987

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 5116 is a single beam mainframe that has a two-colour LCD shutter in front of a CRT with P4 (white) phosphor.

The color shutter works only with the 5D10 digitizer plug-in. The 5116 manual says "The 5116 will not produce color signals if the 5D10 Waveform Digitizer does not have a serial number of B020100 or greater."

The shutter consists of one red and one green polarizer/LCD combinations the size of the visible screen. The 5D10 in turn enables the red shutter, draws the red parts of display, turns on the green shutter in addition, draws the yellow (red+green) parts of the display, then turns off the red shutter, and draws the green parts of the display, at a rate of about 20 Hz. The slow multiplexing rate can lead to color artifacts becoming visible when the observer moves.

In contrast with what is mentioned sometimes, the 5116 does not provide alphanumeric readout. The 5D10 takes care of this.

Key Specifications

  • please add

Pictures

Diagrams