{{Spec | Bandwidth | DC to 15MHz (≤ 3 dB) with [[K|Type K plug-in]]  }}
{{Spec | Bandwidth | DC to 15 MHz (≤ 3 dB) with [[K|Type K plug-in]]  }}
{{Spec | Rise time | 0.024 μs }}
{{Spec | Rise time | 0.024 μs }}
{{Spec | Line Voltage | 108/115/122/216/230/244 V<sub>AC</sub> ±10%,selected via soldering wire on transformer, 50 Hz to 60 Hz. }}
{{Spec | Line Voltage | 108/115/122/216/230/244 V<sub>AC</sub> ±10%, selected via soldering wire on transformer, 50 Hz to 60 Hz }}
{{Spec | Thermal Protection | Automatic resetting thermal cutout, in case internal temperature exceeds safe operating level }}
{{Spec | Thermal Protection | Automatic resetting thermal cutout, in case internal temperature exceeds safe operating level }}
{{Spec | Power Consumption | 500W with [[CA| CA plug-in]] }}
{{Spec | Power Consumption | 500 W with [[CA| CA plug-in]] }}
{{Spec | Cooling  | AC Fan }}
{{Spec | Cooling  | AC Fan }}
{{Spec | Trigger Modes (533)| AC/DC/AC Slow, and HF Sync}}
{{Spec | Trigger Modes (533)| AC/DC/AC Slow, and HF Sync}}
Line 40: Line 40:
{{Spec | Screen Area | 6 cm × 10 cm}}
{{Spec | Screen Area | 6 cm × 10 cm}}
{{Spec | Construction  | Aluminum alloy chassis. Anodized front panel}}
{{Spec | Construction  | Aluminum alloy chassis. Anodized front panel}}
{{Spec | Weight| 61,5 lbs / 27,8 kg }}
{{Spec | Weight| 61.5 lbs / 27.8 kg }}
{{EndSpecs}}
{{EndSpecs}}



Revision as of 00:24, 18 March 2019

Manuals – Specifications – Links – Pictures


The Tektronix Type 533 is a 15 MHz oscilloscope introduced in 1958 that uses letter-series and 1-series plug-ins.

It is similar to a 535, but without the second, delayed timebase. Instead, it has a range of horizontal magnifiers from ×2 to ×100.

There is also a rack-mount version, the RM33. Later 533A have BNC connectors. The standard CRT for the 533 and 533A is the T5330-2. Difference between 533 and 533A is only trigger mode.

Key Specifications

Bandwidth DC to 15 MHz (≤ 3 dB) with Type K plug-in
Rise time 0.024 μs
Line Voltage 108/115/122/216/230/244 VAC ±10%, selected via soldering wire on transformer, 50 Hz to 60 Hz
Thermal Protection Automatic resetting thermal cutout, in case internal temperature exceeds safe operating level
Power Consumption 500 W with CA plug-in
Cooling AC Fan
Trigger Modes (533) AC/DC/AC Slow, and HF Sync
Trigger Modes (533A) AC/DC/AC LF Reject, and HF Sync
Anode Potential 10 kV
Screen Area 6 cm × 10 cm
Construction Aluminum alloy chassis. Anodized front panel
Weight 61.5 lbs / 27.8 kg


Internals

The vertical amplifier consists of a 12BY7 differential amplifier followed by a 6DJ8 cathode-follower, followed by a 6197 differential (common-cathode) output stage that drives the 200 ns L-C delay line, which drives the vertical deflection plates of the CRT.

Trigger pickoff is taken after the cathode follower stage in the vertical amplifier. There is a 6DJ8 differential trigger pickoff amplifier followed by half of a 6DJ8 a cathode follower, buffering the trigger signal.

The trigger circuit is a 6DJ8 trigger amplifier followed by a 6DJ8 Schmitt trigger. Triggering can be from the internal pickoff or from an external signal or "line" trigger, from a 6.3 V tap on the power transformer.

The 533 contains a 53 °C (128 °F) thermal cutoff. The high voltages for the CRT, +8,650 V and −1,350 V, are generated by a 60 kHz Hartley power oscillator and five 5642 high-voltage rectifier diode tubes.