5403: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
summary=60 MHz mainframe | | summary=60 MHz mainframe | | ||
image=Tek 5403 operating.jpg | | image=Tek 5403 operating.jpg | | ||
caption=Tektronix 5403 | | caption=Tektronix 5403/[[D40]] ([[5440]]) | | ||
introduced=1974 | | introduced=1974 | | ||
discontinued=1975 | | discontinued=1975 | | ||
Line 10: | Line 10: | ||
}} | }} | ||
The '''Tektronix 5403''' is a 60 MHz scope mainframe base unit that uses [[5000-series plug-ins]]. It allows CRT readout of settings when used with plug-ins that support this. Most 60 MHz plug-ins and | The '''Tektronix 5403''' is a 60 MHz scope mainframe base unit that uses [[5000-series plug-ins]]. It allows CRT readout of settings when used with plug-ins that support this. Most 60 MHz plug-ins and time bases do. | ||
It was sold preconfigured with a display unit: | It was sold preconfigured with a display unit: | ||
* a [[D40]] single beam unit would make it a 5440 single beam (but multi-trace, depending on plug-ins) oscilloscope, | * a [[D40]] single beam unit would make it a [[5440]] single beam (but multi-trace, depending on plug-ins) oscilloscope, | ||
* a D41 storage display unit would make it a | * a [[D41]] storage display unit would make it a [[5441|5441 CRT storage scope]], | ||
* a D44 dual beam display unit would make it a 5444 dual beam oscilloscope | * a [[D44]] dual beam display unit would make it a [[5444|5444 dual beam oscilloscope]]. | ||
Many scopes have a nameplate on top carrying the 5403 base unit model number instead of the full model (5440, 5441, 5444), sometimes confusing owners. | Many scopes have a nameplate on top carrying the 5403 base unit model number instead of the full model (5440, 5441, 5444), sometimes confusing owners. | ||
[[Category:5000 series storage mainframes]] | [[Category:5000 series storage mainframes]] |
Revision as of 11:21, 15 March 2018
The Tektronix 5403 is a 60 MHz scope mainframe base unit that uses 5000-series plug-ins. It allows CRT readout of settings when used with plug-ins that support this. Most 60 MHz plug-ins and time bases do.
It was sold preconfigured with a display unit:
- a D40 single beam unit would make it a 5440 single beam (but multi-trace, depending on plug-ins) oscilloscope,
- a D41 storage display unit would make it a 5441 CRT storage scope,
- a D44 dual beam display unit would make it a 5444 dual beam oscilloscope.
Many scopes have a nameplate on top carrying the 5403 base unit model number instead of the full model (5440, 5441, 5444), sometimes confusing owners.