What is the difference between the 564 and 564B?
564 are tube base oscilloscope
564B are fully solid state mainframe.


* [http://bama.edebris.com/download/tek/564/tek%20564.v6.pdf Tektronix 564 Manual (PDF)]
* [http://bama.edebris.com/download/tek/564/tek%20564.v6.pdf Tektronix 564 Manual (PDF)]
Line 27: Line 28:
Image:Tek rm564 inside bottom.jpg|RM564, Chassis bottom
Image:Tek rm564 inside bottom.jpg|RM564, Chassis bottom
Image:Tek 564 display.Jpg|564, Display
Image:Tek 564 display.Jpg|564, Display
Image:R564B_1.JPG|R564B w auto-erase and 3A6 and 3B3
</gallery>
</gallery>

Revision as of 23:01, 27 July 2012

The Type 564 is the storage scope of the 560 series. It was introduced in June 1962. The left plug-in directly drives the vertical deflection plates of the CRT. The right plug-in directly drives the horizontal deflection plates. The 564 is a bench scope. The RM564 is the rack-mount version. There is also a 564B. Mod 121N added auto-erase.

Steve Ditter says:

Tek offered two phosphors for the 564. You can determine which one you have by reading the CRT part number, visible in the window in the shield where the deflection plate connections are. 154-0410-00 is P200, which was the standard tube. The 154-0418-00 is the P201, which has faster writing rate, but at the expense of about 30% shorter useful life.

564 are tube base oscilloscope 564B are fully solid state mainframe.