* [http://w140.com/tek_5b25n.pdf Tektronix 5B25N Service Manual (no schematics | * [[Media:070-2813-00.pdf|Tektronix 5B25N Service Manual (1982 revision, complete, with schematics)]] | ||
* [http://w140.com/tek_5b25n.pdf Tektronix 5B25N Service Manual (1986 revision, incomplete, no schematics)] | |||
[[Category:Manual needed]] | [[Category:Manual needed]] | ||
}} | }} | ||
The '''Tektronix 5B25N''' is a "digitizer time base" for the [[5223]] scope, i.e. a time base that also contains a sample clock generator. | The '''Tektronix 5B25N''' is a "digitizer time base" for the [[5223]] scope, i.e. a time base that also contains a sample clock generator. | ||
It will also operate in 5400-series mainframes as a generic time base. | |||
The 5B25N/5223 system uses real-time sampling at sweep rates of 0.1 ms/div or slower. | |||
At sweep rates of 50 us/div or faster, equivalent-time sampling is used. | |||
The 5B25N uses the [[155-0109-01]] trigger chip (U95). | |||
{{BeginSpecs}} | {{BeginSpecs}} |
Revision as of 18:45, 9 November 2017
The Tektronix 5B25N is a "digitizer time base" for the 5223 scope, i.e. a time base that also contains a sample clock generator. It will also operate in 5400-series mainframes as a generic time base. The 5B25N/5223 system uses real-time sampling at sweep rates of 0.1 ms/div or slower. At sweep rates of 50 us/div or faster, equivalent-time sampling is used. The 5B25N uses the 155-0109-01 trigger chip (U95).
Key Specifications
Sweep | 200 ns/Div to 5 s/Div, 1—2—5 |
---|---|
Triggering | > 0.4 Div or 50 mV to 1 MHz, > 0.6 Div or 200 mV to 20 MHz |
X-Y mode | 50 mV/Div, 180 ns rise time, 2 MHz bandwidth, 1 MΩ // 24 pF input |
Features |
|