5B42: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
title=Tektronix 5B42 | | title=Tektronix 5B42 | | ||
summary=60 MHz dual timebase plug-in | | summary=60 MHz dual timebase plug-in | | ||
series=[[ | series=[[5400-series scopes]] | | ||
image=Tek 5b42 1.JPG | | image=Tek 5b42 1.JPG | | ||
caption=Tektronix 5B42 | | caption=Tektronix 5B42 | | ||
Line 10: | Line 10: | ||
* [http://w140.com/tek_5b42.pdf Tektronix 5B42 Manual (PDF)] | * [http://w140.com/tek_5b42.pdf Tektronix 5B42 Manual (PDF)] | ||
}} | }} | ||
The '''Tektronix 5B42''' is a 60 MHz | The '''Tektronix 5B42''' is a 60 MHz dual timebase plug-in for [[5400-series scopes]]. | ||
{{ | {{BeginSpecs}} | ||
{{Spec | Main Sweep | 100 ns/Div to 5 s/Div, 1−2−5; ×10 magnifier (i.e. down to 10 ns/Div), variable ×2.5 (i.e. up to 12.5 s/Div) }} | |||
{{Spec | Delayed Sweep | 100 ns/Div to 0.1 s/Div, 1−2−5 }} | |||
{{Spec | Delay Time | 0.2 to 10 times the TIME/DIV setting }} | |||
{{Spec | Trigger | DC or 50 Hz (AC) or 7.5 kHz (LF REJ) to 10 MHz at 0.4 Div or 100 mV; 10−60 MHz at 1 Div or 400 mV }} | |||
{{Spec | Ext Trig In | 1 MΩ // 20 pF, max. 350 V DC + peak AC or 350 V<sub>p-p</sub> AC }} | |||
{{Spec | X input | 50 mV/Div, DC or 50 Hz to 2 MHz }} | |||
{{EndSpecs}} | |||
==Internals== | |||
The 5B42 uses several Tek-made ICs − two [[155-0109-01]] trigger circuits, a [[155-0049-00|155-0049-xx]] sweep control, and two [[155-0042-03]] or [[155-0028-00]] Miller integrators. | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek 5b42 1.JPG | |||
Tek 5b42 1.jpg | |||
</gallery> | </gallery> | ||
[[Category: | [[Category:5400 series horizontal plugins]] | ||
Revision as of 04:20, 4 July 2018
Template:Plugin Sidebar 2 The Tektronix 5B42 is a 60 MHz dual timebase plug-in for 5400-series scopes.
Key Specifications
Main Sweep | 100 ns/Div to 5 s/Div, 1−2−5; ×10 magnifier (i.e. down to 10 ns/Div), variable ×2.5 (i.e. up to 12.5 s/Div) |
---|---|
Delayed Sweep | 100 ns/Div to 0.1 s/Div, 1−2−5 |
Delay Time | 0.2 to 10 times the TIME/DIV setting |
Trigger | DC or 50 Hz (AC) or 7.5 kHz (LF REJ) to 10 MHz at 0.4 Div or 100 mV; 10−60 MHz at 1 Div or 400 mV |
Ext Trig In | 1 MΩ // 20 pF, max. 350 V DC + peak AC or 350 Vp-p AC |
X input | 50 mV/Div, DC or 50 Hz to 2 MHz |
Internals
The 5B42 uses several Tek-made ICs − two 155-0109-01 trigger circuits, a 155-0049-xx sweep control, and two 155-0042-03 or 155-0028-00 Miller integrators.