The Tektronix A6901 Ground Isolation Monitor.
[[File:A6901.jpg | thumb | 350px | right]]
The '''Tektronix A6901 Ground Isolation Monitor''' connects between mains power and test equipment
without connecting protective ground, in order to safely allow referencing measurements to a low voltage
instead of ground, or break ground loops.
 
It monitors the floating equipment ground voltage. If the voltage exceeds 40 V peak,
or ground current exceeds a selectable limit of 0.5, 3.5 or 5 mA, the A6901 disconnects
mains power and grounds the test equipment.
 
{{BeginSpecs}}
{{Spec|DC trip voltage| 28 V<sub>RMS</sub> (40 V peak) or ±40 V DC}}
{{Spec|Current trip| ±0.5 mA, ±3.5 mA and ±5 mA max. selectable}}
{{Spec|Trip delay| <200 ms}}
{{Spec|Line voltage|90-128 V; 180-250 V; 48-66 Hz}}
{{Spec|Load power|500 W max.}}
{{EndSpecs}}
 
==Manuals==


* [http://w140.com/tek_a6901.pdf Tektronix A6901 Manual (PDF)]
* [http://w140.com/tek_a6901.pdf Tektronix A6901 Manual (PDF)]


[[File:A6901 principle.jpg | thumb | 350px]]


[[Category:Amplifiers]]
[[Category:Power supplies]]
[[Category:Introduced in 1981]]

Revision as of 03:01, 9 June 2016

The Tektronix A6901 Ground Isolation Monitor connects between mains power and test equipment without connecting protective ground, in order to safely allow referencing measurements to a low voltage instead of ground, or break ground loops.

It monitors the floating equipment ground voltage. If the voltage exceeds 40 V peak, or ground current exceeds a selectable limit of 0.5, 3.5 or 5 mA, the A6901 disconnects mains power and grounds the test equipment.

Key Specifications

DC trip voltage 28 VRMS (40 V peak) or ±40 V DC
Current trip ±0.5 mA, ±3.5 mA and ±5 mA max. selectable
Trip delay <200 ms
Line voltage 90-128 V; 180-250 V; 48-66 Hz
Load power 500 W max.

Manuals