AA501: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
Line 6: Line 6:
It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ and unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <-95 dB (0.0018 %). Residual THD+N is specified as <-90 dB (<0.0032 %).
It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ and unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <-95 dB (0.0018 %). Residual THD+N is specified as <-90 dB (<0.0032 %).


It was one of the first, if not the first, audio analyzer capable of fully automatic measurements without requiring manual reference level setting, range selection or frequency fine-tuning.  It is ideally combined with the [[SG505]] low distortion oscillator.
It was one of the first, if not the first, audio analyzers capable of fully automatic measurements without requiring manual reference level setting, range selection or frequency fine-tuning.  It is ideally combined with the [[SG505]] low distortion oscillator.


The AA501 is two slots wide.
The AA501 is two slots wide.

Revision as of 03:47, 1 October 2021

Tektronix AA501
audio analyzer
Tektronix AA501

Produced from 1980 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix AA501 is a audio analyzer plug-in for the TM500 system.

It provides automated measurement of THD+N and levels (RMS responding) in the range of 10 Hz to 100 kHz. Harmonics are measured up to 300 kHz. It has four built-in weighting filters and allows the user to loop an external filter in. Option 01 adds intermodulation measurement. Input impedance is 100 kΩ and unlike other analyzers with usually 1 MΩ or near-infinite input impedance. Internal THD in the audio band is specified as typically <-95 dB (0.0018 %). Residual THD+N is specified as <-90 dB (<0.0032 %).

It was one of the first, if not the first, audio analyzers capable of fully automatic measurements without requiring manual reference level setting, range selection or frequency fine-tuning. It is ideally combined with the SG505 low distortion oscillator.

The AA501 is two slots wide.

Key Specifications

  • please add

Links

Pictures