}} It is the TM5000 incarnation of the [[DC504A]].


{{MissingSpecs}}
==Specification==
* 5 Digit LED Display
* Frequency Range
** DC coupled: 0 Hz to at least 80 MHz
** AC coupled: 10 Hz to at least 80 MHz
* Sensitivity (sine wave):
** 20 mV RMS (56,6 mV_pp) below 15 MHz
** 35 mV RMS (99 mV_pp) at or below 50 MHz
** 35 mV RMS @ 50 MHz derated down to 175 mV RMS (495 mV_pp) @80 MHz
* Input impedance: 1 MΩ; 20 pF
* Trigger Level Range: -1,5V to +1,5 V
*Maximum Resolution
**Frequency kHz Positions: 0,1 Hz; 1 Hz and 10 Hz (Seven digit resolution possible in overflow kHz position)
**Frequency MHz Positions: 100 Hz and 1 kHz (Nine digit resolution possible in overflow kHz position)
**Period msec Positions: 1µs and 10 µs
**Period sec Positions: 10 ms; 1ms and 0,1 ms
*Trigger Error: 0,5% of one cycle at min, trigger sensitivity
*Internal Standard Time Base (1 MHz)
** Stability: 0°C to +50°C after 30 min warm up: 1E-5
** Long Term Drift: 1E-5 per month
** Accuracy: Adjustable to within 1E-7
*Internal  Time Base Option 1 (5 MHz)
** Stability: 0°C to +50°C after 30 min warm up: eE-7
** Long Term Drift: 1E-7 per month
** Accuracy: Adjustable to within 5E-9
* Display Time: Variable  ~0,1 sec ... ~10 sec and HOLD mode


==Pictures==
==Pictures==

Revision as of 15:10, 26 March 2020

Tektronix DC5004
frequency counter
Tektronix DC5004

Produced from 1989 to (?)

Manuals
  • Manual needed please add
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix DC5004 is a frequency counter plug-in for the TM5000 system. It is the TM5000 incarnation of the DC504A.

Specification

  • 5 Digit LED Display
  • Frequency Range
    • DC coupled: 0 Hz to at least 80 MHz
    • AC coupled: 10 Hz to at least 80 MHz
  • Sensitivity (sine wave):
    • 20 mV RMS (56,6 mV_pp) below 15 MHz
    • 35 mV RMS (99 mV_pp) at or below 50 MHz
    • 35 mV RMS @ 50 MHz derated down to 175 mV RMS (495 mV_pp) @80 MHz
  • Input impedance: 1 MΩ; 20 pF
  • Trigger Level Range: -1,5V to +1,5 V
  • Maximum Resolution
    • Frequency kHz Positions: 0,1 Hz; 1 Hz and 10 Hz (Seven digit resolution possible in overflow kHz position)
    • Frequency MHz Positions: 100 Hz and 1 kHz (Nine digit resolution possible in overflow kHz position)
    • Period msec Positions: 1µs and 10 µs
    • Period sec Positions: 10 ms; 1ms and 0,1 ms
  • Trigger Error: 0,5% of one cycle at min, trigger sensitivity
  • Internal Standard Time Base (1 MHz)
    • Stability: 0°C to +50°C after 30 min warm up: 1E-5
    • Long Term Drift: 1E-5 per month
    • Accuracy: Adjustable to within 1E-7
  • Internal Time Base Option 1 (5 MHz)
    • Stability: 0°C to +50°C after 30 min warm up: eE-7
    • Long Term Drift: 1E-7 per month
    • Accuracy: Adjustable to within 5E-9
  • Display Time: Variable ~0,1 sec ... ~10 sec and HOLD mode

Pictures