Delay line

From TekWiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Delay lines in oscilloscopes allow observation of the leading edge of the trigger event. In the vertical signal path, before the delay line, there is typically a trigger pick-off which supplies an undelayed copy of the vertical signal to the trigger and sweep circuitry. Trigger and sweep circuitry need about 60ns to react when presented with the trigger event. Without a delay line, the trigger event would already have come and gone before the scope can trigger and sweep. By sending the input signal through a delay line, the scope will have triggered and begun sweeping by the time the trigger event emerges from the delay line. Thus, the trigger event is drawn on the screen where the operator can see, photograph, or record it by other means.

The first Tektronix scope to contain a delay line was the 513D, which uses an L-C network. Soon after, the 517 appeared, using 51 feet of RG-63U coaxial cable as a 65 nanosecond delay line. 7000-series scopes use special twin-lead delay cables and have a plug-in option, the 7M11. The delay line in the 519 is a large coil of low-loss air-dielectric semi-rigid coax.

The location of the delay line in the instrument block diagram varies:

Types of Delay Lines

There are five main ways delay lines are implemented in Tektronix scopes

Conventional coaxial cable

Used in 517, 4S1, 3S76, 1S1 and DL-11.

Semi-rigid air-core coax

Used in 519, 113

Unshielded helically wound differential transmission line

Used in 581, 585

Helically wound differential transmission line inside braided shield

Used in 545B, 547

Lumped L-C

Lumped L-C delay lines are used in the 511AD, 513D, 514D, 531/533/535, 541/543/545, 551, 555, and 524. These delay lines must be carefully adjusted for best pulse response. A typical lumped L-C delay line has about 30 sections, and each section typically has an adjustable capacitor. In some applications, lumped L-C delay lines were preferred over distributed delays (e.g., coax) because of impedance. It is possible for a lumped L-C delay line to have a characteristic impedance of 1000 Ω, while most coaxial cables are 125 Ω or less. The high impedance made it possible to run the line straight to the CRT deflection plates and absorb the reflected wave at the amplifier. This was called reverse termination, and it doubled amplifier gain while simplifying amplifier construction. It was first applied to Type 535, at serial number 8628. (101-8627 ran the lumped line between two amplifier chassis with termination on each end, as the 585 and 547 did with helically-wound line later.)

Delay Lines in Sampling Oscilloscopes

The purpose of delay lines in sampling scopes is the same as for conventional non-sampling scopes. Since sampling scopes are often used for observing fast pulses, delay lines are often problematic since they have dispersion, and therefore distort pulse waveforms. For example, the 4S1 contains a delay network while the 4S2 does not. Because of this, the 4S2 is a less convenient instrument, but has faster rise-time than the 4S1. One way around the trade-off between pulse response and convenience is to use random sampling.

See Also