P6021: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 31: Line 31:
==Manuals==
==Manuals==


* [[Media:TEK P6021 Manual.pdf | Tektronix P6021 Manual (PDF), earlier version with termination schematics]]
* [http://w140.com/tek_P6021.pdf Tektronix P6021 Manual (PDF), no schematics]
* [http://w140.com/tek_P6021.pdf Tektronix P6021 Manual (PDF), no schematics]
* [http://w140.com/tek_p6021_1971_cat.pdf Description in 1971 Catalog (PDF)]
* [http://w140.com/tek_p6021_1971_cat.pdf Description in 1971 Catalog (PDF)]

Revision as of 13:44, 6 October 2016

P6021 with passive termination box

The Tektronix P6021 is an AC current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is up to 52 MHz.

The sister model P6022 has higher bandwidth but also a higher LF cut-off frequency and lower peak current rating.

Specifications

P6021 passive P6021 + 134 P6022 passive P6022 + 134
Sensitivity 2 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
1 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
Bandwidth (-3 dB) 60 MHz @ 10 mA/mV > 40 MHz 200 MHz @ 10 mA/mV > 70 MHz
LF limit (-3 dB) 450 Hz @ 2 mA/mV
120 Hz @ 10 mA/mV
< 12 Hz 8500 Hz @ 1 mA/mV
935 Hz @ 10 mA/mV
< 100 Hz
Maximum current 15 Ap-p 6 Ap-p
(> 10 kHz @ 1 mV/mA, > 3 kHz @ 10 mV/mA, < 10 MHz)

Manuals

Pictures