P6135: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(corrected for differences between A and non A model)
No edit summary
Line 20: Line 20:


[[Category:1 MΩ Oscilloscope probes]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:Passive Differential probes]]


[[Category:Introduced in 1987]]
[[Category:Introduced in 1987]]

Revision as of 20:30, 4 December 2020

The Tektronix P6135A is a differential probe pair matched to minimize differences in impedance and signal delay, to maintain CMRR up to 20,000:1 when used with differential amplifiers such as the 7A13 or 7A22.

Key Specifications

Scope input Impedances P6135 1 MΩ//14-17 pF
Scope input Impedances P6135A 1 MΩ//13-17 pF (red tip), 1 MΩ//18-22 pF (black tip) and 1 MΩ//45-49 pF (blue tip)
Attenuation Adjustable to ×10
CMRR 10,000:1 on 11A33, 20,000:1 on 7A13
Max. input ±500 V Maximum Common Mode Voltage