PS503: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
{{TM500 | mfg=Tektronix | type=PS503 | function=triple power supply | class=power supply | image=Tek ps503a.jpg | introduced=1972 | discontinued=1995 |
{{TM500 | mfg=Tektronix | type=PS503 | function=triple power supply | class=power supply | image=Tek ps503a.jpg | introduced=1972 | discontinued=1995 |
manuals=
manuals=
* [[Media:070-1303-00.pdf|Tektronix PS503 Manual (PDF)]]
* [[Media:070-1303-00.pdf|Tektronix PS503 Operator (PDF, 1M, no schema)]]
* [[Media:070-1834-01.pdf|Tektronix PS503A Manual (PDF)]]
* [[Media:070-1834-01.pdf|Tektronix PS503A Instruction (OCR PDF, 5M)]]
* [[Media:061-3171-00.pdf|Tektronix PS503A Mod FF (PDF)]]
* [[Media:061-3171-00.pdf|Tektronix PS503A Mod FF (PDF)]]
* [http://w140.com/smb/PS503A_SM.pdf Tektronix PS503A Manual (OCR, PDF)]
}}
}}



Revision as of 05:16, 13 November 2019

Tektronix PS503
triple power supply
Tektronix PS503

Produced from 1972 to 1995

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix PS503 is a triple power supply plug-in for the TM500 system.


It supplies 0 to −20 V and 0 to +20 V at 0.4 A as well as +5 V at 1 A.

The PS503A version delivers +/- 20 V at 1 A when used in TM500 high-power compartments.

The variable supplies can be adjusted independently or can track one another, and are floating; the 5 V output is ground referenced.

Key Specifications

     — Variable outputs
Output voltage 0 to +20 V and 0 to −20 V
Current limit <100 mA to >1 A (0.4 A for original PS503 or if used in low power compartment)
Ripple and noise <3 mVp-p @ 1 A
     — Fixed output
Output voltage3 5 V ±5%, 1 A (ground referenced)
Current limit fixed 1 A
Ripple and noise <3 mVp-p @ 1 A

Rear interface signals

  • +20 V output (22A)
  • −20 V output (22B)
  • ±20 V common (24A, 24B)

(the connections below require various jumper changes in the PS503 as described in the manual)

  • Remote resistor programming (via 25A, 25B)
  • Remote voltage programming (via 25A, 25B)
  • Remote sensing (+Sense 23A, −Sense 23B)

Pictures