Restoring 1220, 1225 and 1230 keypad: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 1: Line 1:
==Description==
==Description==
[[Image:Bounce(1).jpg|thumb|left|250px|(Pic1) "Bouncing" switch, the second trace is the signal coming out of a schmidt trigger.]]
 
[[Image:Bounce(1).jpg|thumb|left|250px|(Pic1) "Bouncing" switch, the second trace is the signal coming out of a [[Schmitt trigger]].]]
[[Image:Bounce(2).jpg|thumb|right|250px|(Pic2) Registered presses being sent to the LA.]]
[[Image:Bounce(2).jpg|thumb|right|250px|(Pic2) Registered presses being sent to the LA.]]
*The [[1220]], [[1225]] and [[1230]] have a keypad interface for controlling them. The switches are tactile switches with a small spring. Over time they start to become extremely "bouncy". This is due to a number of factors, some including corrosion and weakening springs. Over time this will lead to problems such as the key pad being less responsive and the analyzer registering multiple presses. The following picture shows what the keypad is registering (Pic1).
The [[1220]], [[1225]] and [[1230]] have a keypad interface for controlling them. The switches are tactile switches with a small spring. Over time they start to become extremely "bouncy". This is due to a number of factors, some including corrosion and weakening springs. Over time this will lead to problems such as the keypad being less responsive and the analyzer registering multiple presses.  
<br> <br />
 
<br> <br />
Picture 1 shows what the keypad is registering.
<br> <br />
<div style="clear: both"></div>
<br> <br />
==Fix==
==Fix==
[[Image:Bounce(4).jpg|thumb|left|250px|(Pic3) Keypad switches]]
[[Image:Bounce(4).jpg|thumb|left|250px|(Pic3) Keypad switches]]
[[Image:Bounce(5).jpg|thumb|right|250px|(Pic4) Keypad switches]]
[[Image:Bounce(5).jpg|thumb|right|250px|(Pic4) Keypad switches]]
*The switches that the keypad uses are still being manufactured today. They are C&K D6L90F1LFS. There is also the D6L90F2LFS, they are the exact same except the force required to push the buttons. One takes 1.3 Newtons and the other 2 Newtons (Pic3). The key pad has 26 of them. Replacing them with new ones will fix the excessive bouncing. When de-soldering the switches one has to be careful of burning the PCB and lifting pads because the traces are very small.
The switches that the keypad uses are still being manufactured today. They are C&K D6L90F1LFS. There is also the D6L90F2LFS, they are the exact same except the force required to push the buttons. One takes 1.3 Newtons and the other 2 Newtons (Pic3). The key pad has 26 of them. Replacing them with new ones will fix the excessive bouncing. When de-soldering the switches one has to be careful of burning the PCB and lifting pads because the traces are very small.
* [[Media:D6L90F1LFS.pdf|Datasheet for D6L90F1LFS and D6L90F2LFS ]]
 
<br> <br />
:&rarr; [[Media:D6L90F1LFS.pdf|Datasheet for D6L90F1LFS and D6L90F2LFS ]]
<br> <br />
<div style="clear: both"></div>
<br> <br />
<br> <br />
==Conclusion==
==Conclusion==
[[Image:Bounce(3).jpg|thumb|left|250px|(Pic5) Restored keypad.]]  
[[Image:Bounce(3).jpg|thumb|left|250px|(Pic5) Restored keypad.]]  
*It is not known how long this fix will last, but it makes the unit usable again. After the replacement the signal is now clean after replacing the switches (Pic5).
It is not known how long this fix will last, but it makes the unit usable again. After the replacement the signal is now clean after replacing the switches (Pic5).




[[Category:Repair issues]]
[[Category:Repair issues]]

Revision as of 03:45, 4 May 2019

Description

(Pic1) "Bouncing" switch, the second trace is the signal coming out of a Schmitt trigger.
(Pic2) Registered presses being sent to the LA.

The 1220, 1225 and 1230 have a keypad interface for controlling them. The switches are tactile switches with a small spring. Over time they start to become extremely "bouncy". This is due to a number of factors, some including corrosion and weakening springs. Over time this will lead to problems such as the keypad being less responsive and the analyzer registering multiple presses.

Picture 1 shows what the keypad is registering.

Fix

(Pic3) Keypad switches
(Pic4) Keypad switches

The switches that the keypad uses are still being manufactured today. They are C&K D6L90F1LFS. There is also the D6L90F2LFS, they are the exact same except the force required to push the buttons. One takes 1.3 Newtons and the other 2 Newtons (Pic3). The key pad has 26 of them. Replacing them with new ones will fix the excessive bouncing. When de-soldering the switches one has to be careful of burning the PCB and lifting pads because the traces are very small.

→ Datasheet for D6L90F1LFS and D6L90F2LFS

Conclusion

(Pic5) Restored keypad.

It is not known how long this fix will last, but it makes the unit usable again. After the replacement the signal is now clean after replacing the switches (Pic5).