S-1: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(link)
No edit summary
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Plugin Sidebar |
{{Plugin Sidebar 2|
title=Tektronix S-1 |
title=Tektronix S-1 |
summary=Sampling Head |
summary=Sampling Head |
image=S1-crop.jpg |
image=S1-crop.jpg |
caption=S-1 head |
caption=S-1 head |
series=[[:Category:Sampling plugins|7000/S3 series Sampling Plugins]] |
introduced=1967 |
years=? – ? |
discontinued=1989 |
series={{3S+7S}} |
manuals=
manuals=
* [http://bama.edebris.com/download/tek/s1/s1.djvu Tektronix S-1 Manual (DjVu)]
* [http://bama.edebris.com/download/tek/s1/s1.djvu Tektronix S-1 Manual (DjVu)]
Line 11: Line 12:
}}
}}


The S-1 [[sampling_oscilloscope|sampling]] plug-in head provides a single [[Connectors#GR-874|GR-874]] 50 Ω input with a 350 ps rise-time.  
The S-1 [[sampling_oscilloscope|sampling]] plug-in head provides a single [[GR-874]] 50 Ω input with a 350 ps rise-time.  


The S-1 can be used with the 7000 series of sampling plug-ins, as well as the 3S series of sampling units.
The S-1 can be used with the 7000 series of sampling plug-ins, as well as the 3S series of sampling units.
Line 17: Line 18:
A trigger pickoff is provided for internal triggering, and displayed noise is specified as less than 2 mV.
A trigger pickoff is provided for internal triggering, and displayed noise is specified as less than 2 mV.
The S-1 accepts an input voltage range of -1V to +1V with less than 1 V<sub>p-p</sub> input signal amplitude.
The S-1 accepts an input voltage range of -1V to +1V with less than 1 V<sub>p-p</sub> input signal amplitude.
==Specifications==


{{BeginSpecs}}
{{BeginSpecs}}
Line 45: Line 44:


[[Category:7000 and 3S series sampling heads]]
[[Category:7000 and 3S series sampling heads]]
[[Category:GR874]]

Revision as of 23:45, 8 September 2016

Template:Plugin Sidebar 2

The S-1 sampling plug-in head provides a single GR-874 50 Ω input with a 350 ps rise-time.

The S-1 can be used with the 7000 series of sampling plug-ins, as well as the 3S series of sampling units.

A trigger pickoff is provided for internal triggering, and displayed noise is specified as less than 2 mV. The S-1 accepts an input voltage range of -1V to +1V with less than 1 Vp-p input signal amplitude.

Key Specifications

Rise time 350 ps
Bandwidth 1 GHz
Input impedance 50 Ω (GR-874)
Noise < 2 mV