S-2: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(17 intermediate revisions by 2 users not shown)
Line 1: Line 1:
The S-2 plug-in sampling head provides a single  
{{Plugin Sidebar 2|
[[Connectors#GR-874|GR-874]] 50-ohm input with a 50ps risetime.  
title=Tektronix S-2 |
summary=Sampling Head |
image=Tek s2 front crop.jpg |
caption=S-2 head |
series={{3S+7S}} |
introduced=1967 |
discontinued=1989 |
manuals=
* [http://bama.edebris.com/download/tek/s2/s2.djvu Tektronix S-2 Manual (DjVu)]
* [http://w140.com/tek_s-2.pdf Tektronix S-2 Manual (PDF)]
}}
The '''Tektronix S-2 Sampling Head''' plug-in provides a single  
[[GR-874 connector|GR-874]] 50 Ω input with a 75 ps risetime.  
 
The S-2 can be used in the 7000 series and 3S series of [[sampling oscilloscope|sampling plug-ins]].  
The S-2 can be used in the 7000 series and 3S series of [[sampling oscilloscope|sampling plug-ins]].  
The S-2 provides an internal trigger pickoff signal for internal triggering.  
It provides an internal trigger pickoff signal for internal triggering.  
The noise is specified as less than 10mV.
Noise is specified as less than 10 mV.
 
When the S-2 was first introduced, the rise-time specification was 50 ps, but that
was not achieved in practice, so the rise-time specification was revised to be 75 ps.
 
{{BeginSpecs}}
{{Spec | Rise time | 75 ps }}
{{Spec | Bandwidth | 4.66 GHz eq.}}
{{Spec | Input voltage | -1 to +1 V (max. -5 to +5) }}
{{EndSpecs}}
 
==Pictures==


* [http://bama.edebris.com/download/tek/s2/s2.djvu Tektronix S-2 Manual (DjVu)]
* [http://w140.com/tek_s-2.pdf Tektronix S-2 Manual (PDF)]
<gallery>
<gallery>
Tek s2 front.jpg
S-52 s-2 rt.jpg | [[S-52]] and S-2 give 76 ps rise-time together
S2 schem1.png | schematic
Tek s2 strobe side.jpg | S-2 interior, strobe board side
Tek s2 amp side.jpg | S-2 interior, amplifier board side
Tek s2 bridge in place.jpg | Sampling diodes in place
Tek s2 input term r4.jpg | Input termination resistor
Tek s2 sampler r.jpg | Sampler board, right
Tek s2 sampler l.jpg | Sampler board, left
Tek s2 diode removal.jpg | Diode holder slides out
Tek s2 amp under.jpg | Sampler board underside
Tek s2 amp removed.jpg | S-2 with amplifier board removed
Tek s2 strobe under.jpg | Strobe board underside
Tek s2 strobe removed.jpg | S-2 with strobe board removed
</gallery>


Image:S2 schem1.png
 
</gallery>
[[Category:7000 and 3S series sampling heads]]

Revision as of 01:44, 5 March 2017

Template:Plugin Sidebar 2 The Tektronix S-2 Sampling Head plug-in provides a single GR-874 50 Ω input with a 75 ps risetime.

The S-2 can be used in the 7000 series and 3S series of sampling plug-ins. It provides an internal trigger pickoff signal for internal triggering. Noise is specified as less than 10 mV.

When the S-2 was first introduced, the rise-time specification was 50 ps, but that was not achieved in practice, so the rise-time specification was revised to be 75 ps.

Key Specifications

Rise time 75 ps
Bandwidth 4.66 GHz eq.
Input voltage -1 to +1 V (max. -5 to +5)

Pictures