S-6: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (moved S6 to S-6: Standard Tek designation as printed on face plate includes the dash)
No edit summary
Line 1: Line 1:
[[Image:Impuls_S6.jpg|200px|thumb|right|Impulse taken with S6 sampling head. Every dot is measured at an solely Impulse combined on the CRT with a rate of app. 100Hz. Bright dots are newer than dimmed one.]]
{{Plugin Sidebar |
The S6 sampling plug-in head is a 50 ohm feedthrough unit with a rise-time of 30ps and bandwidth of 11.5GHz. The S6 provides two unterminated 50-ohm SMA connections in a loop-through configuration. The S6 is specified for less than 5mV of noise. Note, that the unit provides no internal trigger pickoff signal for internal triggering! There is no internal termination, always use a termination on the unit to give a minimum protection against electrostatic discharge at handling. It was [[introduced in 1971]].
title=Tektronix S-6 |
 
summary=Sampling Head |
* http://jeroen.web.cern.ch/jeroen/S6/S6.shtml
image=Tek s6 2.jpg |
 
caption=S-6 head |
series=[[:Category:Sampling plugins|7000/S3 series Sampling Plugins]] |
years=1971 – ? |
manuals=
* [http://w140.com/tek_nov1988_s6.pdf Tektronix S-6 Manual (high quality, 1988, PDF)]
* [http://w140.com/tek_nov1988_s6.pdf Tektronix S-6 Manual (high quality, 1988, PDF)]
* [http://w140.com/tek_s6.pdf Tektronix S-6 Manual (low quality, 1987, PDF)]
* [http://w140.com/tek_s6.pdf Tektronix S-6 Manual (low quality, 1987, PDF)]
* [http://w140.com/TEK_S6_1983.pdf Tektronix S-6 Manual (high quality, 1983, PDF)]
* [http://w140.com/TEK_S6_1983.pdf Tektronix S-6 Manual (high quality, 1983, PDF)]
==See also==
}}
[[7S11]]
The S-6 sampling plug-in head is a 50 Ω feedthrough unit with a rise-time of 30 ps and bandwidth of 11.5 GHz. It was [[introduced in 1971]].  The S-6 provides two unterminated 50 Ω SMA connections in a loop-through configuration.  Always use a termination on the unit to give a minimum protection against electrostatic discharge at handling.
 
==Specifications==
 
* Rise time: 30 ps
* Bandwidth: 11.5 GHz
* Input impedance: 50 Ω (unterminated!)
* Noise: < 5 mV of noise
* No internal trigger pick-off signal
* No internal termination
 
==Links==
 
* [http://jeroen.web.cern.ch/jeroen/S6/S6.shtml S-6 internal photo and simulation]


==Pictures==
<gallery>
<gallery>
Image:Impuls_S6.jpg|Impulse taken with S6 sampling head. Every dot is measured at an solely Impulse combined on the CRT with a rate of app. 100Hz. Bright dots are newer than dimmed one.
Image:Tek s-6.jpg
Image:Tek s-6.jpg
Image:Tek s6 2.jpg
Image:Tek s6 2.jpg
</gallery>
</gallery>
[[Category:7000 and 3S series sampling heads]]

Revision as of 07:42, 18 May 2014

{{{manufacturer}}} {{{type}}}
Sampling Head
S-6 head

Compatible with [[7000/S3 series Sampling Plugins]]

Produced from {{{introduced}}} to {{{discontinued}}}

Manuals
[[Category:Introduced in {{{introduced}}}]]
Manuals – Specifications – Links – Pictures

The S-6 sampling plug-in head is a 50 Ω feedthrough unit with a rise-time of 30 ps and bandwidth of 11.5 GHz. It was introduced in 1971. The S-6 provides two unterminated 50 Ω SMA connections in a loop-through configuration. Always use a termination on the unit to give a minimum protection against electrostatic discharge at handling.

Specifications

  • Rise time: 30 ps
  • Bandwidth: 11.5 GHz
  • Input impedance: 50 Ω (unterminated!)
  • Noise: < 5 mV of noise
  • No internal trigger pick-off signal
  • No internal termination

Links

Pictures