T0520

From TekWiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

The Tektronix T0520  (P/N 154-0093-00, 154-0097-00, 154-0102-00, 154-0103-00, 154-0129-00, 154-0162-00, 154-0176-00, 154-0343-00) is a 5" CRT used in the 525, 532, 570, and 575.

It was originally known as the T52. It has an unaluminized face and is typically operated with 4 kV of total acceleration voltage, e.g., +2300 V on the anode and −1700 V on the cathode.

The T0520 is known as the 5CAPxx in the EIA system.

Specifications

With 4000 V total acceleration voltage:

  • horizontal sensitivity: 21 V/cm
  • vertical sensitivity: 9.9 V/cm

Part numbers

Part No Name Phosphor
154-0093-00 (154-093) T0520-1 (T52 P1) P1
154-0097-00 (154-097) T0520-2 (T52 P2) P2
154-0102-00 (154-102) T0520-7 (T52 P7) P7
154-0103-00 (154-103) T0520-11 (T52 P11) P11
154-0129-00 (154-129) T0520-5 (T52 P5) P5
154-0162-00 (154-162) T0520-16 (T52 P16) P16
154-0176-00 (154-176) T0520-19 (T52 P19) P19
154-0343-00 (154-343) T0520-31 (T52 P31) P31

Data

Links

Used in

Some instruments using part T0520

Instrument Manufacturer Class Model Description Introduced
525 Tektronix Oscilloscope 525 TV waveform monitor 1955
532 Tektronix Oscilloscope 532 5 MHz oscilloscope 1955
570 Tektronix Curve Tracer 570 Curve tracer for tubes 1955
575 Tektronix Curve Tracer 575 Curve tracer for transistors 1957

Pictures