TWD120: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
(formatting)
Line 5: Line 5:
introduced=1994 |
introduced=1994 |
discontinued=1995 |
discontinued=1995 |
summary=100MHz, 100MS/s 8-bit 2-channel digitizer  |
summary=100 MHz, 100 MS/s 8-bit 2-ch digitizer  |
manuals=
manuals=
* [http://www.ko4bb.com/getsimple/index.php?id=download&file=Tektronix/Tektronix_Miscelaneous/Tektronix_TWD120_Digitizer_Operator_Manual.zip Tektronix TWD 120 Digitizer Instruction Manual (ZIP)]
* [http://www.ko4bb.com/getsimple/index.php?id=download&file=Tektronix/Tektronix_Miscelaneous/Tektronix_TWD120_Digitizer_Operator_Manual.zip Tektronix TWD 120 Digitizer Instruction Manual (ZIP)]
*[http://www.ko4bb.com/getsimple/index.php?id=download&file=Tektronix/Tektronix_TWD120_Digitizer_Operator_Manual.pdf Tektronix TWD 120 Digitizer Reference Manual (PDF)]
* [http://www.ko4bb.com/getsimple/index.php?id=download&file=Tektronix/Tektronix_TWD120_Digitizer_Operator_Manual.pdf Tektronix TWD 120 Digitizer Reference Manual (PDF)]
}}
}}


Line 17: Line 17:
The Adaptec ASPI SCSI driver is required for the software to communicate with the digitizer. SCSI configuration can be tricky.
The Adaptec ASPI SCSI driver is required for the software to communicate with the digitizer. SCSI configuration can be tricky.


==Specifications==
{{BeginSpecs}}
===Acquisition===
{{SpecGroup|Acquisition}}
* Sample rate: 2 channels @ 100MS/s each (two digitizers)
{{Spec | Bandwidth | 100 MHz (20 MHz selectable limit) }}
* Analog bandwidth: 100MHz on both channels (20MHz selectable limit)
{{Spec | Sample rate | 2 channels @ 100 MS/s each (two digitizers) }}
* Resolution: 8 bit
{{Spec | Resolution | 8 bit }}
* Record lengths: 500 to 5000 samples per channel
{{Spec | Record length | 500 to 5000 samples per channel }}
* Modes: sample, envelope, average (16 samples), high-resolution, and peak-detect
{{Spec | Modes | sample, envelope, average (16 samples), high-resolution, and peak-detect }}


===Analog inputs===
{{SpecGroup | Inputs}}
* Voltage:
{{Spec | Deflection | 2 mV/div - 99.5 mV/div (±1 V offset), 100 mV/div - 995 mV/div (±10 V offset),  1 V/div - 10 V/div (±100 V offset) }}
** ±400V (DC + peak AC) up to 100kHz
{{Spec | Max. input | ±400 V (DC + peak AC) up to 100 kHz, derate −20 dB/decade up to 3 MHz, 13 V<sub>p-p</sub> above 3 MHz }}
** -20dB/decade up to 3MHz
{{Spec | Input impedance | 1 MΩ }}
** 13Vpk above 3MHz
* Impedance: 1M&Omega;
* Coupling: DC, AC, GND
* Ranges:
** 2mV/div - 99.5mV/div (&#177;1V offset)
** 100mV/div - 995mV/div (&#177;10V offset)
** 1V/div - 10V/div (&#177;100V offset)


===Trigger===
{{SpecGroup | Trigger}}
* Modes: edge, error, external and video (NTSC, SECAM, PAL, Sync negative or positive)
{{Spec | Trigger modes | edge, error, external and video (NTSC, SECAM, PAL, Sync negative or positive) }}
* Source: CH1, CH2, External
{{Spec | Trigger Source | CH1, CH2, External }}
* Coupling: AC, noise reject, high frequency reject, low frequency reject
{{Spec | Trigger coupling |  AC, noise reject, high frequency reject, low frequency reject }}
* Levels: &#177;12 divisions (CH1, CH2) or up to &#177;15V (External)
{{Spec | Trigger levels | ±12 divisions (CH1, CH2) or up to ±15 V (External) }}
* Holdoff: 500ns to 10s
{{Spec | Trigger holdoff |  500 ns to 10 s }}


===Misc===
{{SpecGroup | Misc }}
* Display: N/A on the unit. Depends on the host PC.
{{Spec | Interfaces |
* Ports:
* [[Ultra SCSI II]] (50-pin high density) for host connection
** Ultra SCSI II (50-pin high density)
* [[RS-232 interface]] (DE-9)  
** [[RS-232]] (DE-9)  
* [[Parallel printer interface]] (DB-25)
** Centronics-A (DB-25)
}}
*Probe compensation output: 5V @ 1kHz (1M&Omega; load)
{{Spec | Calibrator output | 5 V @ 1 kHz (1 MΩ load) }}
*Power:
{{Spec | Power | 12−24 V<sub>DC</sub>, 30 W max }}
** 12-24VDC
 
** 30W max
{{EndSpecs}}


== Links ==
== Links ==

Revision as of 02:50, 29 August 2019

{{{manufacturer}}} 
100 MHz, 100 MS/s 8-bit 2-ch digitizer
Tektronix TWD120

Produced from 1994 to 1995

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix TWD 120 Digitizer allows a Windows PC to be used as a digital storage oscilloscope. It is rated at 100 MHz, has two input channels and an external trigger input. It connects to the host PC via a SCSI bus.

The TWD 120 is about the size of a laptop, and was supplied with a soft case. It was intended to be used in conjunction with a laptop running Windows 3.1, and was apparently manufactured for GE for use by medical device field technicians.

The Adaptec ASPI SCSI driver is required for the software to communicate with the digitizer. SCSI configuration can be tricky.

Key Specifications

     — Acquisition
Bandwidth 100 MHz (20 MHz selectable limit)
Sample rate 2 channels @ 100 MS/s each (two digitizers)
Resolution 8 bit
Record length 500 to 5000 samples per channel
Modes sample, envelope, average (16 samples), high-resolution, and peak-detect
     — Inputs
Deflection 2 mV/div - 99.5 mV/div (±1 V offset), 100 mV/div - 995 mV/div (±10 V offset), 1 V/div - 10 V/div (±100 V offset)
Max. input ±400 V (DC + peak AC) up to 100 kHz, derate −20 dB/decade up to 3 MHz, 13 Vp-p above 3 MHz
Input impedance 1 MΩ
     — Trigger
Trigger modes edge, error, external and video (NTSC, SECAM, PAL, Sync negative or positive)
Trigger Source CH1, CH2, External
Trigger coupling AC, noise reject, high frequency reject, low frequency reject
Trigger levels ±12 divisions (CH1, CH2) or up to ±15 V (External)
Trigger holdoff 500 ns to 10 s
     — Misc
Interfaces
Calibrator output 5 V @ 1 kHz (1 MΩ load)
Power 12−24 VDC, 30 W max

Links

Photos