If you get the "Sorry, the file cannot be displayed. There seems to be a technical issue ..." error when trying to view an image, please make sure you access the site at http://w140.com/tekwiki/, not www.w140.com/tekwiki/ (with "www"). Sorry for the inconvenience - we are looking for a generic solution.

P6149

From TekWiki
Jump to: navigation, search
Tektronix P6149

The Tektronix P6149 is a passive ×10 voltage probe with a specified −3 dB point of 50 MHz. The impedance at the tip is 10 MΩ in parallel with 15.5 pF.

The probe connects to the oscilloscope with a BNC connector, and the compensation range is 20 pF to 62 pF.

The maximum input voltage is 500 V at DC, decreasing to about 25 V at 50 MHz.