Line 4: Line 4:
The triggering signal passes through a [[6DJ8]]-based differential amplifier and then is discriminated by a  
The triggering signal passes through a [[6DJ8]]-based differential amplifier and then is discriminated by a  
[[6DJ8]]-based Schmitt trigger.  As is usual for [[560-series scopes]], the vertical deflection plates of the CRT
[[6DJ8]]-based Schmitt trigger.  As is usual for [[560-series scopes]], the vertical deflection plates of the CRT
are driven directly by the vertical plug-in.  Aside from being [[dual-beam]], the 565 is unusual among the  
are driven directly by the vertical plug-in.  Aside from being dual-beam, the 565 is unusual among the  
other 560-series models in the fact that it has built-in trigger, sweep and horizontal amplifier circuits.
other 560-series models in the fact that it has built-in trigger, sweep and horizontal amplifier circuits.
It is also unusual in that it employs a tunnel diode in the trace intensification circuit.  The tunnel diode
It is also unusual in that it employs a tunnel diode in the trace intensification circuit.  The tunnel diode
forms as a bistable multivibrator: kick it one way and it turns on and stays on, kick it the other way and
forms as a bistable multivibrator: kick it one way and it turns on and stays on, kick it the other way and
it turns off and stays off.
it turns off and stays off.