The triggering signal passes through a [[6DJ8]]-based differential amplifier and then is discriminated by a | The triggering signal passes through a [[6DJ8]]-based differential amplifier and then is discriminated by a | ||
[[6DJ8]]-based Schmitt trigger. As is usual for [[560-series scopes]], the vertical deflection plates of the CRT | [[6DJ8]]-based Schmitt trigger. As is usual for [[560-series scopes]], the vertical deflection plates of the CRT | ||
are driven directly by the vertical plug-in. Aside from being | are driven directly by the vertical plug-in. Aside from being dual-beam, the 565 is unusual among the | ||
other 560-series models in the fact that it has built-in trigger, sweep and horizontal amplifier circuits. | other 560-series models in the fact that it has built-in trigger, sweep and horizontal amplifier circuits. | ||
It is also unusual in that it employs a tunnel diode in the trace intensification circuit. The tunnel diode | It is also unusual in that it employs a tunnel diode in the trace intensification circuit. The tunnel diode | ||
forms as a bistable multivibrator: kick it one way and it turns on and stays on, kick it the other way and | forms as a bistable multivibrator: kick it one way and it turns on and stays on, kick it the other way and | ||
it turns off and stays off. | it turns off and stays off. |