Z: Difference between revisions
No edit summary |
No edit summary |
||
(21 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
The Tektronix Type Z is a comparator plug-in for [[500-series scopes]]. | {{Plugin Sidebar 2| | ||
Its maximum sensitivity is | title=Tektronix Type Z| | ||
summary=Comparator preamp plug-in| | |||
image=Tek z front.jpg | | |||
caption=Type Z front view| | |||
introduced=1960 | | |||
discontinued=1969 | | |||
series=[[500-series scopes]]| | |||
manuals= | |||
* [http://w140.com/mmm/tek-z.pdf Tektronix Type Z Manual (PDF)] | |||
* [http://bama.edebris.com/manuals/tek/z/ Tektronix Type Z Manual (BAMA, offline?)] | |||
<!-- * [http://w140.com/tek_fcp/tek_type_z_factory_cal_proc.pdf Tektronix Type Z Factory Calibration Procedure (PDF)] --> | |||
* [[Media:070-251.pdf|Tektronix Type Z Manual (PDF, OCR, bad-OCR)]] | |||
* [[Media:tek_type_z_bama_manual.pdf|Tektronix Type Z Manual (BAMA, PDF, OCR, bad-OCR)]] | |||
* [[Media:tek_type_z_fcp.pdf|Tektronix Type Z Factory Calibration Procedure (PDF, OCR)]] | |||
}} | |||
The '''Tektronix Type Z''' is a comparator plug-in for [[500-series scopes]]. | |||
Its two main subsystems are a differential amplifier and a precision variable | |||
DC voltage source, which can be used as one of the amplifier inputs. | |||
This allows DC-coupled measurements of small signals with large DC offsets. | |||
Its maximum sensitivity is 50 mV/div, and it achieves 40,000 to 1 common-mode | |||
rejection at DC and low frequencies. Its risetime as a general-purpose | rejection at DC and low frequencies. Its risetime as a general-purpose | ||
amplifier is | amplifier is 27 ns (13 MHz bandwidth), but it can track a common-mode risetime of 7 ns. | ||
Type Z has two inputs, A and B, plus a precision comparison voltage, | The Type Z has two inputs, A and B, plus a precision comparison voltage, V<sub>C</sub>, that is | ||
adjustable from 0 to +/- | adjustable from 0 to +/-1 V, 10 V, or 100 V via a ten-turn pot. It's possible to | ||
view A, -B, A-B, A- | view V<sub>A</sub>, -V<sub>B</sub>, V<sub>A</sub>-V<sub>B</sub>, | ||
V<sub>A</sub>-V<sub>C</sub>, or V<sub>C</sub>-V<sub>B</sub>. | |||
Unlike later comparators, it has a separate step attenuator for each input, | Unlike later comparators, it has a separate step attenuator for each input, | ||
permitting | permitting the user to view the difference between signals of widely differing amplitudes. | ||
It is also the only comparator that can handle +/- | It is also the only comparator that can handle +/- 100 V common mode at full sensitivity. | ||
The Type Z uses two [[turret attenuators]]. | |||
With a pair of "Disconnect Signal" buttons, Type Z was the first movement toward a " | With a pair of "Disconnect Signal" buttons, the Type Z was the first of the | ||
position on the input switches. | movement toward a "GND" position on the input switches. | ||
Type Z was [[introduced in 1960]] and uses both tubes and transistors, | The Type Z was [[introduced in 1960]] and uses both tubes and transistors, | ||
capitalizing on each | capitalizing on the strengths of each. It was dropped after 1968. | ||
The Type [[P6023]] probe, introduced in 1962 with R and C compensation, | The Type [[P6023]] probe, [[introduced in 1962]] with R and C compensation, | ||
was specifically designed for Type Z but also marketed for Type [[G]]. | was specifically designed for the Type Z but also marketed for the Type [[G]]. | ||
* http:// | ==Specifications== | ||
[[Category:Specifications needed]] ''please add'' | |||
==Links== | |||
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/Z.html Type Z @ amplifier.cd] | |||
==Pictures== | |||
<gallery> | |||
Tek z front.jpg|Front View | |||
Tek z left.jpg|Left Side | |||
Tek_z_schem.png|Schematic | |||
Tek_z_turret.png|Attenuators | |||
Tek z 1.jpg | |||
Tek z 2.jpg | |||
Tek z 3.jpg | |||
Tek z 4.jpg | |||
Tek z 5.jpg | |||
Tek z 6.jpg | |||
Tek z 7.jpg | |||
Tek type z pre-prod.jpg|Pre-production Type Z with different knob color. | |||
</gallery> | |||
[[Category:500 series plugins]] | |||
[[Category:Differential amplifiers]] |
Revision as of 16:17, 14 October 2018
Template:Plugin Sidebar 2 The Tektronix Type Z is a comparator plug-in for 500-series scopes. Its two main subsystems are a differential amplifier and a precision variable DC voltage source, which can be used as one of the amplifier inputs. This allows DC-coupled measurements of small signals with large DC offsets. Its maximum sensitivity is 50 mV/div, and it achieves 40,000 to 1 common-mode rejection at DC and low frequencies. Its risetime as a general-purpose amplifier is 27 ns (13 MHz bandwidth), but it can track a common-mode risetime of 7 ns.
The Type Z has two inputs, A and B, plus a precision comparison voltage, VC, that is adjustable from 0 to +/-1 V, 10 V, or 100 V via a ten-turn pot. It's possible to view VA, -VB, VA-VB, VA-VC, or VC-VB.
Unlike later comparators, it has a separate step attenuator for each input, permitting the user to view the difference between signals of widely differing amplitudes. It is also the only comparator that can handle +/- 100 V common mode at full sensitivity. The Type Z uses two turret attenuators.
With a pair of "Disconnect Signal" buttons, the Type Z was the first of the movement toward a "GND" position on the input switches.
The Type Z was introduced in 1960 and uses both tubes and transistors, capitalizing on the strengths of each. It was dropped after 1968.
The Type P6023 probe, introduced in 1962 with R and C compensation, was specifically designed for the Type Z but also marketed for the Type G.
Specifications
please add
Links
Pictures
-
Front View
-
Left Side
-
Schematic
-
Attenuators
-
-
-
-
-
-
-
-
Pre-production Type Z with different knob color.