3C66: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 16: Line 16:
is due to the settling time of the envelope detector.  In addition to the vertical
is due to the settling time of the envelope detector.  In addition to the vertical
defection signal, the 3C66 provides a front panel output of the measured signal.
defection signal, the 3C66 provides a front panel output of the measured signal.
* [http://bama.edebris.com/download/tek/3c66/tek%203c66.v6.pdf Tektronix 3C66 Manual (PDF)]


<gallery>
<gallery>

Revision as of 09:30, 22 January 2012

The Tektronix 3C66 Carrier Amplifier is a plug-in introduced in 1963 for 560-series scopes. It is designed to amplify signals from transducers such as strain gauges, whose impedance varies based on, for example, mechanical strain. These transducers are usually connected in a bridge circuit. The 3C66 drives the bridge with a 25kHz "carrier" signal, which is modulated by the relative impedances of the arms of the bridge. The resulting signal is amplified and envelope-detected by the 3C66, producing a vertical deflection proportional to the the measured quantity (strain, for example).

The 3C66 provides built-in variable impedances for balancing the bridge. Because the carrier is 25kHz, the maximum bandwidth of the measured quantity is 5kHz. This limitation is due to the settling time of the envelope detector. In addition to the vertical defection signal, the 3C66 provides a front panel output of the measured signal.