P6008: Difference between revisions
No edit summary |
(Deleted old "dead" link, corrected temperature ratings, minor additions to descriptions) |
||
Line 4: | Line 4: | ||
|summary=Passive 66 MHz, x10 probe | |summary=Passive 66 MHz, x10 probe | ||
|image=Tek p6008 1.JPG | |image=Tek p6008 1.JPG | ||
|caption=P6008 | |caption=Early P6008 | ||
|for=1 MΩ scope inputs | |for=1 MΩ scope inputs | ||
|introduced=(?) | |introduced=(?) | ||
Line 10: | Line 10: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:070-0362-01.pdf|Tektronix P6008 Manual, 1963 (PDF, needs OCR)]] | * [[Media:070-0362-01.pdf|Tektronix P6008 Manual, 1963 (PDF, needs OCR)]] | ||
* [[Media:070-1173-00.pdf|Tektronix P6008 ENVIRONMENTAL PROBE Manual, 1971 (PDF)]] | * [[Media:070-1173-00.pdf|Tektronix P6008 ENVIRONMENTAL PROBE Manual, 1971 (PDF)]] | ||
}} | }} | ||
There | There are two different versions, or generations, of the '''Tektronix P6008''' ×10 passive voltage probe. | ||
Each was fitted with a BNC connector with no readout encoding pin. | |||
===010-0130-00=== | ===010-0130-00=== | ||
The '''early (1963) P6008 Probe (010-0130-00)''' was primarily designed for use with the [[82|Type 82]] and [[86|Type 86]] plug-ins in a [[580-series_scopes|580-series scope]], with 15 pF inputs. | The '''early (1963) P6008 Probe (010-130 & 010-0130-00)''' was primarily designed for use with the [[82|Type 82]] and [[86|Type 86]] plug-ins in a [[580-series_scopes|580-series scope]], with 15 pF inputs. | ||
It came with a 3.5 foot cable. | It came with a 3.5 foot gray cable. | ||
Like the other members of the monolithic probe family, the early P6008 was rated for temperatures up to 75 C. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 29: | Line 30: | ||
===010-0130-01=== | ===010-0130-01=== | ||
The '''later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01)''' can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. | The '''later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01)''' can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. | ||
It came with a 6 foot cable. | It came with a 6 foot white cable. | ||
This later version of the P6008 was rated for temperatures up to 150 C for the probe and cable and up to 55 C for the compensation box. | |||
{{BeginSpecs}} | {{BeginSpecs}} |
Revision as of 10:59, 5 December 2021
There are two different versions, or generations, of the Tektronix P6008 ×10 passive voltage probe. Each was fitted with a BNC connector with no readout encoding pin.
010-0130-00
The early (1963) P6008 Probe (010-130 & 010-0130-00) was primarily designed for use with the Type 82 and Type 86 plug-ins in a 580-series scope, with 15 pF inputs. It came with a 3.5 foot gray cable. Like the other members of the monolithic probe family, the early P6008 was rated for temperatures up to 75 C.
Key Specifications
Attenuation | 10 × ±3% with 1 MΩ ±2% scope input |
---|---|
Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) |
Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) |
Input capacitance | ~7 pF |
010-0130-01
The later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01) can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. It came with a 6 foot white cable. This later version of the P6008 was rated for temperatures up to 150 C for the probe and cable and up to 55 C for the compensation box.
Key Specifications
Attenuation | 10 × ±3% with scope input at 1 MΩ ±2% |
---|---|
Compensation range | 15 pF to 55 pF |
Bandwidth | 100 MHz w/15 pF scope inputs |
Input capacitance | 10-14 pF, depending on scope input capacitance |
Pictures
-
Early P6008 Probe
-
Early Compensating Box Internals