P6008: Difference between revisions
(Deleted old "dead" link, corrected temperature ratings, minor additions to descriptions) |
No edit summary |
||
Line 34: | Line 34: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation | 10 × ±3% with | {{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | ||
{{Spec | Compensation range | 15 pF to 55 pF }} | {{Spec | Compensation range | 15 pF to 55 pF }} | ||
{{Spec | Bandwidth | 100 MHz w/15 pF scope inputs }} | {{Spec | Bandwidth | 100 MHz w/15 pF scope inputs }} | ||
Line 43: | Line 43: | ||
<gallery> | <gallery> | ||
Tek p6008 1.JPG | Early P6008 Probe | Tek p6008 1.JPG | Early P6008 Probe | ||
P6008_Int-1.jpeg | Early Compensating Box Internals | P6008_Int-1.jpeg | Early P6008 Compensating Box Internals | ||
</gallery> | </gallery> | ||
[[Category:1 MΩ Oscilloscope probes]] | [[Category:1 MΩ Oscilloscope probes]] |
Revision as of 13:49, 7 December 2021
There are two different versions, or generations, of the Tektronix P6008 ×10 passive voltage probe. Each was fitted with a BNC connector with no readout encoding pin.
010-0130-00
The early (1963) P6008 Probe (010-130 & 010-0130-00) was primarily designed for use with the Type 82 and Type 86 plug-ins in a 580-series scope, with 15 pF inputs. It came with a 3.5 foot gray cable. Like the other members of the monolithic probe family, the early P6008 was rated for temperatures up to 75 C.
Key Specifications
Attenuation | 10 × ±3% with 1 MΩ ±2% scope input |
---|---|
Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) |
Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) |
Input capacitance | ~7 pF |
010-0130-01
The later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01) can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. It came with a 6 foot white cable. This later version of the P6008 was rated for temperatures up to 150 C for the probe and cable and up to 55 C for the compensation box.
Key Specifications
Attenuation | 10 × ±3% with 1 MΩ ±2% scope input |
---|---|
Compensation range | 15 pF to 55 pF |
Bandwidth | 100 MHz w/15 pF scope inputs |
Input capacitance | 10-14 pF, depending on scope input capacitance |
Pictures
-
Early P6008 Probe
-
Early P6008 Compensating Box Internals