The | The '''Tektronix P6015''' is a 1000X high-voltage probe usable up to 20 kV (40 kV peak pulse). It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak). The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used. | ||
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants. | The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants. | ||
[[File:Tek P6015 derating.jpg|300px|thumb|right|Derating curves]] | [[File:Tek P6015 derating.jpg|300px|thumb|right|Derating curves]] | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation ratio | | {{Spec | Attenuation ratio | 1000X }} | ||
{{Spec | Input impedance | 100 MΩ // 3 pF }} | {{Spec | Input impedance | 100 MΩ // 3 pF }} | ||
{{Spec | Rise time | 4.67 | {{Spec | Rise time | 4.67 nsec (10' cable), 14 nsec (25' cable) }} | ||
{{Spec | Bandwidth | 75 MHz }} | {{Spec | Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) }} | ||
{{Spec | Compensation Range | 15-50 pF }} | |||
{{Spec | Max. input voltage | | {{Spec | Max. input voltage | | ||
* With dielectric filling: 20 kV DC or RMS to 100 kHz, pulse up to 40 kV (10%, < 0.1s) | * With dielectric filling: 20 kV DC or RMS to 100 kHz, pulse up to 40 kV (10%, < 0.1s) | ||
Line 16: | Line 19: | ||
[[File:Tek P6015 term box.jpg|300px|thumb|right|Termination box]] | [[File:Tek P6015 term box.jpg|300px|thumb|right|Termination box]] | ||
==Manuals== | ==Manuals== | ||
* [http://w140.com/p6015.pdf Tektronix P6015 Manual (Copyright date 1963, PDF)] | * [http://w140.com/p6015.pdf Tektronix P6015 Manual (Copyright date 1963, PDF)] | ||
* [http://w140.com/P6015_070-0373-02.pdf Tektronix P6015 Manual (Revision date 1985, PDF)] | * [http://w140.com/P6015_070-0373-02.pdf Tektronix P6015 Manual (Revision date 1985, PDF)] | ||
Line 25: | Line 28: | ||
==Links== | ==Links== | ||
* [[Media:US3256484.pdf|US Patent 3,256,484]] | * [[Media:US3256484.pdf | US Patent 3,256,484]] | ||
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/P6015.html P6015A @ amplifier.cd] | * [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/P6015.html P6015A @ amplifier.cd] | ||
* [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com] | * [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com] | ||
Line 33: | Line 36: | ||
P6015 BW.png | P6015 BW.png | ||
Tek p6015 schem.png | Tek p6015 schem.png | ||
Tek hv dielectric fluid.jpg|Can of Dielectric Fluid | Tek hv dielectric fluid.jpg|Can of Freon Dielectric Fluid | ||
Tek_P6015_1.jpg | Tek_P6015_1.jpg | ||
Tek_P6015_2.jpg | Tek_P6015_2.jpg | ||
Line 39: | Line 42: | ||
Tek_P6015_4.jpg | Tek_P6015_4.jpg | ||
</gallery> | </gallery> | ||
[[Category:1 MΩ Oscilloscope probes]] | [[Category:1 MΩ Oscilloscope probes]] | ||
[[Category:High voltage oscilloscope probes]] | [[Category:High voltage oscilloscope probes]] |
Revision as of 10:10, 8 December 2021
The Tektronix P6015 is a 1000X high-voltage probe usable up to 20 kV (40 kV peak pulse). It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak). The original filling material, Freon-114 aka Fluorocarbon 114 (R-114, CFC-114), is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
Key Specifications
Attenuation ratio | 1000X |
---|---|
Input impedance | 100 MΩ // 3 pF |
Rise time | 4.67 nsec (10' cable), 14 nsec (25' cable) |
Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) |
Compensation Range | 15-50 pF |
Max. input voltage |
|