434: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 8: | Line 8: | ||
The signal passes through rotary cam-operated input attenuators, then a JFET source-follower buffer | The signal passes through rotary cam-operated input attenuators, then a JFET source-follower buffer | ||
that uses a [[2N5911|2N5911A]] (Tektronix part number 151-1032-00). | that uses a [[2N5911|2N5911A]] (Tektronix part number 151-1032-00) biased with a drain current of 12.5mA | ||
and Vgs of -0.26V. | |||
* [http://w140.com/tektronix_434_service.pdf Tektronix 434 Manual sn 500,000 and up (complete, PDF)] | * [http://w140.com/tektronix_434_service.pdf Tektronix 434 Manual sn 500,000 and up (complete, PDF)] |
Revision as of 16:21, 14 July 2013
The 434 is a analog CRT storage scope with two independent storage areas on the screen. It has a bandwith of 24 MHz and uses a tunnel diode in its trigger circuit. The storage is done in the CRT itself, by trapping charge on a special fine grid of isolated pads behind the phosphor where the electron beam is then blocked or released.
There is a chopped two channel system and the fastest sweep time is 20ns/div. An option for a tube with higher sensitivity at high writing speeds was available (OPT. 01).
The signal passes through rotary cam-operated input attenuators, then a JFET source-follower buffer that uses a 2N5911A (Tektronix part number 151-1032-00) biased with a drain current of 12.5mA and Vgs of -0.26V.
- Tektronix 434 Manual sn 500,000 and up (complete, PDF)
- Tektronix 434 Manual sn below 500,000 (complete, PDF)
- Tektronix 434 Manual (incomplete, PDF)