|manufacturer=Tektronix | |||
|model=P6010 | |||
|summary=~150 MHz, ×10, Passive Probe | |||
|image=Tek p6010 1.JPG | |||
|caption=P6010 | |||
|for=1 MΩ scope inputs | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:070-0495-01.pdf|Tektronix P6010 Manual]] (OCR) | |||
}} | |||
The ''' Tektronix P6010''' is a x10 miniature passive probe designed for use with Tektronix wide-band oscilloscopes. | |||
{{BeginSpecs}} | |||
{{Spec | Attenuation | ×10 }} | |||
{{Spec | Rise time | ≤2 ns (probe), 7 ns with [[453]] scope }} | |||
{{Spec | Bandwidth | 150 MHz }} | |||
{{Spec | Input impedance | 10 MΩ // <10–14.5 pF, depending on cable length }} | |||
{{Spec | Compensation range | 14-21 pF, factory compensated to 20 pF }} | |||
{{Spec | Maximum voltage | 500 V DC + peak AC, derate above 12 MHz }} | |||
{{Spec | Cable length | 3.5, 6, or 9 feet long, terminated in a [[BNC]] connector }} | |||
{{EndSpecs}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek p6010 1.JPG | |||
Tek p6010 2.JPG | |||
Tek p6010 3.JPG | |||
Tek p6010 4.JPG | |||
Tek p6010 5.JPG | |||
Tek p6010 6.JPG | |||
P6010.jpg | |||
</gallery> | </gallery> | ||
[[Category:1 | [[Category:1 MΩ Oscilloscope probes]] |
Latest revision as of 06:32, 14 February 2023
The Tektronix P6010 is a x10 miniature passive probe designed for use with Tektronix wide-band oscilloscopes.
Key Specifications
Attenuation | ×10 |
---|---|
Rise time | ≤2 ns (probe), 7 ns with 453 scope |
Bandwidth | 150 MHz |
Input impedance | 10 MΩ // <10–14.5 pF, depending on cable length |
Compensation range | 14-21 pF, factory compensated to 20 pF |
Maximum voltage | 500 V DC + peak AC, derate above 12 MHz |
Cable length | 3.5, 6, or 9 feet long, terminated in a BNC connector |