I picked up a barn find and the 7B92A looked in good shape until I spotted U244 - a dual op amp MC1458N 8 DIP
==Exploded U244==
I picked up a barn find and the 7B92A looked in good shape until I spotted U244 - a dual op amp MC1458N 8 DIP:


<gallery>
<gallery>
Line 6: Line 7:


From the service manual:
From the service manual:
  Internal Source (SN B070000-above). When the
<blockquote>
Delayed Trigger Generator is using an internal trigger
Internal Source (SN B070000-above). When the Delayed Trigger Generator is using an internal trigger
signal, the internal trigger signal from the vertical channel
signal, the internal trigger signal from the vertical channel of the oscilloscope is connected to the Delayed Trigger
of the oscilloscope is connected to the Delayed Trigger
Generator through J250. Signals above 30 kilohertz are coupled through C246 to pin 14 of U274 . (Pins 13 and 14 of
Generator through J250. Signals above 30 kilohertz are
U274 are internally connected.) Signals below 30 kilohertz  are connected to amplifier U244 through R257. The output
coupled through C246 to pin 14 of U274 . (Pins 13 and 14 of
of amplifier U244 is coupled, along with the offset from the LEVEL control, to pin 1 of U274.
U274 are internally connected.) Signals below 30 kilohertz
</blockquote>
  are connected to amplifier U244 through R257. The output
 
of amplifier U244 is coupled, along with the offset from the
I'm hoping that U274 didn't get damaged by whatever catastrophe has hit...
LEVEL control, to pin 1 of U274.
[[User:Qfissler|Qfissler]] ([[User talk:Qfissler|talk]]) 03:05, 16 October 2023 (PDT)

Latest revision as of 03:05, 16 October 2023

Exploded U244

I picked up a barn find and the 7B92A looked in good shape until I spotted U244 - a dual op amp MC1458N 8 DIP:

From the service manual:

Internal Source (SN B070000-above). When the Delayed Trigger Generator is using an internal trigger signal, the internal trigger signal from the vertical channel of the oscilloscope is connected to the Delayed Trigger Generator through J250. Signals above 30 kilohertz are coupled through C246 to pin 14 of U274 . (Pins 13 and 14 of U274 are internally connected.) Signals below 30 kilohertz are connected to amplifier U244 through R257. The output of amplifier U244 is coupled, along with the offset from the LEVEL control, to pin 1 of U274.

I'm hoping that U274 didn't get damaged by whatever catastrophe has hit... Qfissler (talk) 03:05, 16 October 2023 (PDT)