2630: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(9 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Instrument Sidebar  
title=Tektronix 2630 |
|class=Spectrum Analyzer
summary=Fourier Analyzer DC to 20 kHz |
|manufacturer=Tektronix  
image= Tek 2630 1.jpg |
|model=2630  
caption=Tektronix 2630 |
|summary=20 kHz Fourier Analyzer
introduced=1989 |
|image=Tek 2630 1.jpg  
discontinued=1995 |
|caption=Tektronix 2630  
manuals=
|introduced=1989  
Need Service Manual
|discontinued=1995  
* [[Media:070-7239-01.pdf|Tektronix 2630 Service Manual (PDF, needs OCR)]]
|designers=
* [[Media:Tek_2600_Series_Catalog_1989.pdf| Tektronix 2630 Introduction Spec (PDF)]]
|manuals=
* [[Media:Tek_2600_Series_Catalog_1994.pdf| Tektronix 2622 Final Spec (PDF)]]
* [[Media:070-7239-01.pdf|Tektronix 2630 Service Manual]]
* [[Media:Tek_2600_Series_Catalog_1989.pdf| Tektronix 2630 Introduction Spec]]
* [[Media:Tek_2600_Series_Catalog_1994.pdf| Tektronix 2630 Final Spec]]
}}
}}
 
The '''Tektronix 2630''' is a Fourier analyzer for electrical, mechanical, and electromechanical applications in the DC to 20 kHz frequency range.  Typical applications are Structural Analysis, Control Systems, Machine Vibration, Audio and Acoustic Tests, and General Purpose Signal and System Analysis.
The '''Tektronix 2630''' is a Fourier analyzer links dedicated signal acquisition and analysis with a personal computer’s mass storage and graphics.  It allows measurement solutions for electrical, mechanical, and electromechanical applications in the DC to 20 kHz frequency range.  Typical applications are Structural Analysis, Control Systems, Machine Vibration, Audio and Acoustic Tests, and General Purpose Signal and System Analysis.


Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally.  Signal processing includes Fourier Transform (FFT) and Spectral Lines.  The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary.  With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected.
Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally.  Signal processing includes Fourier Transform (FFT) and Spectral Lines.  The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary.  With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected.
Line 19: Line 20:
The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops.  All of the data acquisition, data management, signal processing and other computationally intensive operations are reserved for the Fourier Analyzer’s high-performance measurement and analysis hardware.  Built-in analog and digital anti-alias filters automatically track all of the bandwidth settings.  A selection of frame sizes allows the user to choose the best trade-off between acquisition time and frequency resolution.  When high frequency resolution around a specific signal is needed, the option "zoom" feature can be used.  It allows one to focus up to 1600 spectral line with a span as small as 10 Hz about the frequency of interest.
The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops.  All of the data acquisition, data management, signal processing and other computationally intensive operations are reserved for the Fourier Analyzer’s high-performance measurement and analysis hardware.  Built-in analog and digital anti-alias filters automatically track all of the bandwidth settings.  A selection of frame sizes allows the user to choose the best trade-off between acquisition time and frequency resolution.  When high frequency resolution around a specific signal is needed, the option "zoom" feature can be used.  It allows one to focus up to 1600 spectral line with a span as small as 10 Hz about the frequency of interest.


'''[[wikipedia:Fast_Fourier_transform|Fast Fourier transform]]''' (FFT) is an algorithm that computes the [[wikipedia:Discrete_Fourier_transform|descrete Fourier transform]] (DFT) of a sequence, or its inverse (IDFT).  [[Wikipedia:Fourier_analysis|Fourier analysis]] converts a signal from its original domain (often time or space) to a representation in the [[Wikipedia:Frequency_domain|frequency domain]] and vice versa..
To learn more about FFT read '''[[wikipedia:Fast_Fourier_transform|Wikipedia article on Fast Fourier transform]].


[[File:FFT_of_Cosine_Summation_Function.png|center|500px|Fourier analysis]]
Front panel inputs/outputs are: CH1, CH2, CH3, and CH4 each with a [[BNC connector]] (1 MΩ; 200 pF; ±30 V); and OUTPUT [[BNC connector]] (50 Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.)
 
Front panel inputs/outputs are: CH1, CH2, CH3, and CH4 each with a [[BNC connector]] (1 MΩ; 200 pF; ±30 V); and OUTPUT [[BNC connector]] (50Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.)


Rear panel inputs/outputs are: SYSTEM INTERCONNECT [[DB9 connector]] (Male connector used for both External triggering, and External sampling inputs.  All pins TTL-level except Signal ground: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; pin 9 is the external sampling input); and SERIAL PORT [[BNC connector]] (Female connector used linking to the host computer via a Tektronix supplied serial interface cable).
Rear panel inputs/outputs are: SYSTEM INTERCONNECT [[DB9 connector]] (Male connector used for both External triggering, and External sampling inputs.  All pins TTL-level except Signal ground: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; pin 9 is the external sampling input); and SERIAL PORT [[BNC connector]] (Female connector used linking to the host computer via a Tektronix supplied serial interface cable).


---------------------------------------------------------
<div style='text-align: center;'>Specifications based on 2000 published documentation, unless otherwise specified.</div>
{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Frequency Ranges | DC to 20 kHz }}
{{Spec | Frequency | DC to 20 kHz }}
{{Spec | Max Real-time Bandwidth | 10 kHz }}
{{Spec | Max Real-time Bandwidth | 10 kHz }}
{{Spec | Dynamic Range | 75 dB }}
{{Spec | Dynamic Range | 75 dB }}
{{Spec | Standard Channels | 2 }}
{{Spec | Standard Channels | 2 }}
{{Spec | Max Channels | 4 }}
{{Spec | Max Channels | 4 }}
{{Spec | Channel Match | ±0.2 dB }}
{{Spec | Transient Capture Samples | 500 K, extended to 1.5M with Opt. 2M (2 MB) }}
{{Spec | Transient Capture Samples | 500 K, extended to 1.5M with Opt. 2M (2 MB) }}
{{Spec | Spectral Lines | 25 to 1600 }}  
{{Spec | Spectral Lines | 25 to 1600 }}  
Line 52: Line 50:
* Opt. 4H: Signal Generator
* Opt. 4H: Signal Generator
* Opt. 5H: Data Record/Playback
* Opt. 5H: Data Record/Playback
 
==Software==
* [[Media:Tektronix-2622,2630,2641,2642,Software_and_app._utilies_for_Tek_26xx_Fourier_Analyzer_2.26-2600.zip|DOS software and applications for 2622, 2630, 2641 and 2642]]
==Pictures==
==Pictures==
<gallery>
<gallery>
Line 67: Line 66:
</gallery>
</gallery>


[[Category: Spectrum Analyzers]]
[[Category:Spectrum analyzers]]

Latest revision as of 16:17, 9 March 2024

Tektronix 2630
20 kHz Fourier Analyzer
Tektronix 2630

Produced from 1989 to 1995

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 2630 is a Fourier analyzer for electrical, mechanical, and electromechanical applications in the DC to 20 kHz frequency range. Typical applications are Structural Analysis, Control Systems, Machine Vibration, Audio and Acoustic Tests, and General Purpose Signal and System Analysis.

Each of the channel inputs provide simultaneous sampling of all channels utilizing 12 bit ADC standard or 16 bit ADC optionally. Signal processing includes Fourier Transform (FFT) and Spectral Lines. The signal generator has a wide variety of functions, like sine, square, sawtooth, triangle, input, random, adjustable random, chirp, and arbitrary. With the optional TurboPac Application Library and Run-Time License advanced measurement calculations and graphs can be generated from the data collected.

The PC’s monitor displays the measurements results – but that’s where the Fourier Analyzer dependence on the PC stops. All of the data acquisition, data management, signal processing and other computationally intensive operations are reserved for the Fourier Analyzer’s high-performance measurement and analysis hardware. Built-in analog and digital anti-alias filters automatically track all of the bandwidth settings. A selection of frame sizes allows the user to choose the best trade-off between acquisition time and frequency resolution. When high frequency resolution around a specific signal is needed, the option "zoom" feature can be used. It allows one to focus up to 1600 spectral line with a span as small as 10 Hz about the frequency of interest.

To learn more about FFT read Wikipedia article on Fast Fourier transform.

Front panel inputs/outputs are: CH1, CH2, CH3, and CH4 each with a BNC connector (1 MΩ; 200 pF; ±30 V); and OUTPUT BNC connector (50 Ω; ±10 V; signal general output capable of a variety of pre-defined, as well as user-defined, signals.)

Rear panel inputs/outputs are: SYSTEM INTERCONNECT DB9 connector (Male connector used for both External triggering, and External sampling inputs. All pins TTL-level except Signal ground: Pin 1 triggering signal input; pin 2 trigger sense output; pin 3 external clock input; pins 6 thru 8 signal ground; pin 9 is the external sampling input); and SERIAL PORT BNC connector (Female connector used linking to the host computer via a Tektronix supplied serial interface cable).

Key Specifications

Frequency DC to 20 kHz
Max Real-time Bandwidth 10 kHz
Dynamic Range 75 dB
Standard Channels 2
Max Channels 4
Channel Match ±0.2 dB
Transient Capture Samples 500 K, extended to 1.5M with Opt. 2M (2 MB)
Spectral Lines 25 to 1600
Input Impedance 1 MΩ; 200 pF
Max Input Level ±30 V
Included Accessories User Guide; Instrument Program Software; System Simulator Box; Power Cord; and Serial Interface Cable (please specify)
Weight Standard accessories: 7.7 kg (17 lbs)
Power 90 − 250 VAC, 48 to 66 Hz, >120 W
Operating Atmospherics Temperatures: 0 °C to +50 °C; Humidity: 95% for five days; Altitude: Up to 4.8 km (15,000 ft)

Options

  • Opt. 1H: Four Input Channels
  • Opt. 2H: 2-CH Zoom
  • Opt. 2M: Large Data Memory (add 2 MB)
  • Opt. 3H: 4-CH Zoom
  • Opt. 4H: Signal Generator
  • Opt. 5H: Data Record/Playback

Software

Pictures