32,959
edits
No edit summary |
No edit summary |
||
(131 intermediate revisions by 8 users not shown) | |||
Line 1: | Line 1: | ||
{{Instrument Sidebar | |||
|manufacturer=Tektronix | |||
|model=545 | |||
|class=Oscilloscope | |||
|series=500-series scopes | |||
|image=Tek_545a_291_1.jpg | |||
|caption=Tektronix 545A front view | |||
|introduced=1955 | |||
|discontinued=1974 | |||
|summary=30 (33) MHz oscilloscope | |||
|designers=John Gates;Dave Barton;Bob Shand | |||
|manuals= | |||
'''545''' | |||
* [[Media:070-198.pdf|Tektronix 545 Manual]] | |||
* [[Media:535_545_operators_handbook.pdf|Tektronix 535 and 545 Operators Handbook]] (OCR) | |||
* [[Media:tek_545_fcp.pdf|545 Factory Calibration Procedure, September 1959]] (OCR) | |||
* [[Media:Tek_545_calibration_and_maintenance_procedure.pdf|Tektronix 545 Calibration and Maintenance Procedure]] | |||
* [[Media:tek_545_calibration_maintenance_proc.pdf|Tektronix 545 Calibration and Maintenance Procedure]] (bad-OCR) | |||
* [[Media:Tek 545 mod 112.pdf|Tektronix 545 Mod 112]] | |||
Type 545 was [[introduced in 1955|introduced February 7th, 1955]] | '''545A''' | ||
along with | * [[Media:070-163.pdf|545A Instruction]] (OCR) | ||
which was in turn superseded in 1964 by | * [[Media:Using your 535A or 545A.pdf|Using your 535A or 545A (1960)]] | ||
The difference between the 545A and 545 is the control ergonomics, | * [[Media:Operators Handbook 535A 545A 1959.pdf|Tektronix 535A and 545A Operator's Handbook 1959]] | ||
not any major circuit design changes. | * [[Media:tek_545a_fcp_early.pdf|545A Factory Calibration Procedure, January 1961]] (OCR) | ||
* [[Media:tek_545a_fcp.pdf|545A Factory Calibration Procedure, July 1961]] (OCR) | |||
'''545B''' | |||
* [[Media:070-428.pdf|Tektronix 545B Manual 070-428]]<br /><small>Alternate: [https://bama.edebris.com/download/tek/545b/545b.djvu DJVu @ BAMA]</small> | |||
The | * ''[[Media:070-438.pdf|RM543B manual 070-438 needed]]'' | ||
The | * [[Media:Tek 545b irb.pdf|Tektronix 545B Instrument Reference Book]] (OCR) | ||
* [[Media:Tek 545b fcp jan 1966.pdf|Tektronix 545B Factory Calibration Procedure, January 1966]] | |||
* [[Media:Tek 545b fcp tlc up to jan 1969.pdf|Tektronix 545B Factory Calibration Procedure, January 1969]] | |||
* [[Media:Tek 545b eis march 1964.pdf|Tektronix 545B Engineering Instrument Specification]] | |||
'''Maintenance and calibration''' | |||
* [https://w140.com/tek_balancing_545_vert.pdf Balancing the 540-Series Vertical Amplifier] (OCR) | |||
* [https://w140.com/tek_fcp/tek_adjust_540_vert_delay.pdf How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope] | |||
* [https://w140.com/navair_17-20aw-08.pdf Navair 17-20AW-08 Manual, which discusses the 545] | |||
}} | |||
The '''Tektronix Type 545''' is a 30 (33) MHz scope that takes [[letter-series and 1-series plug-ins]]. It has two timebases, which allows delayed triggering. | |||
Type 545 was [[introduced in 1955|introduced February 7th, 1955]] along with Type [[541]], and superseded in 1959 by Type 545A, | |||
which was in turn superseded in 1964 by Type 545B, which was produced until 1973. Type [[543]], which is a 541 with 100x sweep magnifier, was [[introduced in 1958]]. | |||
The difference between the 545A and 545 is the control ergonomics, not any major circuit design changes. | |||
The main improvement was to replace a pair of switches for the time base (8-position Time/Div and 6-position multiplier) | |||
with a single 24-position switch, freeing up front panel space for a Time Base B Trigger Mode rotary switch. | |||
Additionally, the delaying timebase on the 545A supports delays up to 10 seconds while the 545 supports delays only up to 100 milliseconds. | |||
The older 545 uses the [[T54|T54 / 5BHP2]] CRT, P2 [[phosphor]] was standard. | |||
The 545A uses the [[T5430]] CRT for which also P2 phosphor was standard. | |||
The newer 545B came with the further improved [[T5470]] CRT (also used in the [[543B]], [[544]], [[546]] and [[547]]) and P31 phosphor as standard. | |||
== Versions == | |||
There were also rack-mount versions. Types RM41 and RM45 were [[introduced in 1957|introduced in October 1957]], | |||
and | Types RM41A and RM45A were [[introduced in 1959|introduced in May 1959]] simultaneously with their bench counterparts, | ||
and the rackmount Type RM545B or R545B was introduced at the same time as Type 545B. | |||
Clones of the 545A are the [[Lavoie LA-265A]] and [[Hickok 1805A]]. These clones were not licensed by Tektronix. | |||
Some feel that Type 547 replaced Type 545, but this is not quite true; | === Relationship of 545B to 547 === | ||
Types 545B and 546/547 were introduced simultaneously. | Some feel that [[547|Type 547]] replaced Type 545, but this is not quite true; Types 545B and [[546]]/[[547]] were introduced simultaneously ([[introduced in 1964|1964]]). | ||
It is more correct to say that the | It is more correct to say that the 50 MHz 546 and 547 were upgrades. (Type 544 is likewise the upgrade for 541/543.) | ||
( | |||
The Type | The Type [[K|53K/54K]] plug-in was introduced with the 545 and 541, and until Type [[L|53/54L]] came out in 1957, | ||
and until Type [[L|53/54L]] came out in 1957, | |||
it was the only plug-in that could take full advantage of their bandwidth. | it was the only plug-in that could take full advantage of their bandwidth. | ||
There was never a full-speed dual-trace plug-in | There was never a full-speed dual-trace plug-in — that would wait until Types [[1A1]] and [[1A2]], which came out with the 545B. | ||
Types [[1A1]] and [[1A2]], which came out with the 545B. | |||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 30 MHz (33 MHz with a 50 MHz plug-in such as Type [[1A1]]) }} | |||
{{SpecGroup|545B}} | |||
{{Spec | Sweep | 0.1 μs/div to 5 s/div, 1−2−5 }} | |||
{{Spec | CRT | [[T5470]]-31-2, 10 kV acceleration }} | |||
{{Spec | Probes | 2 P6006 probes with BNC connectors }} | |||
{{EndSpecs}} | |||
''please add'' | |||
==Links== | |||
{{Documents|Link=545}} | |||
{{Documents|Link=545A}} | |||
{{Documents|Link=545B}} | |||
==Internals== | |||
Early 545 units have [[selenium rectifiers]]. Later units have silicon rectifiers. | |||
A modification kit, [[040-0395-00]], converts a 545 from selenium rectifiers to silicon rectifiers. | |||
The trigger circuit used a [[6DJ8]] tube in the 545 and 545A. NPN transistors are used in the 545B trigger circuit. | |||
=== 545 and 545A Vertical Path === | |||
Types 545 and 545A have a six stage differential [[distributed amplifier|distributed vertical amplifier]] made of twelve [[6DK6]] tubes. | |||
The vertical amplifier used in the 545A is also used in the [[551]] and [[555]]. | |||
The 545 uses the [[154-098]] CRT. With the limited CRT technology available at the time, the higher bandwidth of the 541 and 545 came with a tradeoff. | |||
The vertical scale is only 4 divisions, 2 above and 2 below the graticule center line. | |||
The lower bandwidth 531/[[Type 533|533]]/535 retained the 6 vertical divisions, as used in most other Tektronix scopes. | |||
Shorting the outputs of the vertical amplifier to ground can cause expensive damage by burning out the termination resistor network. | |||
Starting at Type 545A serial number 29960, there is a 150 mA fuse, F1054, to prevent that failure. | |||
This change was made available for instruments already built, in Modification Kit 040-227. | |||
=== 545B Vertical Path === | |||
Type 545B differs significantly from the 545 and 545A. | |||
It was designed by [[Dave Barton]]. | |||
It has a partly solid-state, non-distributed vertical amp, and uses the [[154-0478-00]] CRT which is also used in the [[544]], [[546]], and [[547]]. Improvements in CRT design, including reduced deflection plate capacitance and increased sensitivity, increased the vertical scale in the 545B from 4 to 6 divisions. The improved CRT also uses a ceramic envelope, with a flat glass faceplate with internal graticule markings to eliminate parallax errors. | |||
==Links== | |||
* J.Evans' [http://www.thevalvepage.com/testeq/tek/545a/545a.htm 545A page] / [http://www.thevalvepage.com/testeq/tek/545b/545b.htm 545B page] | |||
* radiomuseum.org: [https://www.radiomuseum.org/r/tektronix_oszilloskop_545.html 545] / [https://www.radiomuseum.org/r/tektronix_545a545.html 545A] / [https://www.radiomuseum.org/r/tektronix_oscilloscope_545b.html 545B] | |||
* Richard Sears: [https://richardsears.wordpress.com/2013/04/21/tektronix-535a-and-545a/ Tektronix 535A and 545A] | |||
* barrytech.com: [http://www.barrytech.com/tektronix/vintage/tek545.html 545] / [http://www.barrytech.com/tektronix/vintage/tek545a.html 545A] / [http://www.barrytech.com/tektronix/vintage/tek545b.html 545B] | |||
==Pictures== | |||
===545=== | |||
<gallery> | |||
Tek 545 trace.jpg | |||
Tek 545 early 1.jpg|545, early style | |||
Tek 545 early 2.jpg|545, early style | |||
Tek 545 early 3.jpg|545, early style | |||
Tek 545 early 4.jpg|545, early style | |||
Tek 545 early 5.jpg|545, early style | |||
Tek 545 early 6.jpg|545, early style | |||
Tek 545 distributed amplifier on.jpg|Distributed amplifier | |||
Tek 545 vertical rackmount.jpg|545 in vertical rackmount form | |||
Tek 545 silicon rectifier mod.JPG|545 with mod that adds silicon rectifiers in place of selenium rectifiers | |||
Tek 545 ad - Electronics - 1955-08.jpg | Tek 545 ad, ''Electronics'', August 1955 | |||
</gallery> | |||
< | ===545A=== | ||
<gallery> | |||
Tek-545A-front.jpg | |||
Tek 545a 291 1.jpg | 545A front | |||
Tek 545a 291 2.jpg | |||
Tek 545a 291 3.jpg | |||
Tek 545a 291 4.jpg | |||
Tek 545a 291 5.jpg | |||
Tek 545a 291 6.jpg | 545A interior, right side | |||
Tek 545a 291 7.jpg | 545A interior, left side | |||
Tek-545a-right1.jpg | 545A interior, right side detail (time base B chassis open) | |||
Tek-545a-timebase-a.jpg | 545A interior, right side detail (time base A) | |||
Tek-545a-timebase-b.jpg | 545A interior, right side detail (time base B) | |||
Tek-545a-hv-1.jpg | 545A interior, HV supply | |||
Tek-545a-hv-2.jpg | 545A interior, HV supply | |||
Tek-545a-hv-osc.jpg | 545A interior, HV oscillator tube | |||
Tek-545a-rectifier.jpg | 545A interior, rectifier | |||
Tek-545a-bottom1.jpg | 545A interior, bottom view | |||
Tek-545a-bottom2.jpg | 545A interior, bottom view (DC voltage regulator section detail) | |||
Tek-545a-bottom3.jpg | 545A interior, bottom view (distributed amplifier section detail) | |||
Tek 545a delay line.jpg | 545A Delay line | |||
Tek_545a_blockdiagram.png | 545A block diagram | |||
545a_vert.png | 545A signal path | |||
Tek 545a close trace.jpg| 545A trace | |||
Tek 545a handbook compartment1.jpg|545A handbook compartment | |||
Tek 545a handbook compartment2.jpg|545A handbook compartment | |||
Tek 545a on 202-1.jpg|545A on a Tek 202-1 cart | |||
Tek 545a controls.jpg|545A controls | |||
Tek 545a trace.jpg|545A trace | |||
Tek 545a trace2.jpg|545A trace | |||
</gallery> | |||
===RM45A=== | |||
<gallery> | |||
Tek rm45a 34.jpg | RM45A, standard color | |||
Tek rm45a rear.jpg | RM45A rear | |||
Tek rm45a 1.jpg | Brown-face RM45A | |||
Tek rm45a 2.jpg | |||
Tek rm45a 3.jpg | |||
Tek rm45a 4.jpg | |||
Tek rm45a 5.jpg | |||
Tek rm45a 6.jpg | |||
Tek rm45a 7.jpg | |||
Tek rm45a 8.jpg | |||
Tek rm45a 9.jpg | |||
Tek rm45a 10.jpg | |||
Tek rm45a 404.jpg|RM 45A with standard B timebase | |||
Tek rm45a on pallet.jpg|RM 45A with raster B timebase, MOD 116B | |||
tek_rm45a_goddard.jpg|RM45A from NASA | |||
</gallery> | |||
===545B=== | |||
<gallery> | <gallery> | ||
Tek 545b front.jpg | 545B front | |||
545B guernsey.JPG | a british made 545B (Tektronix Guernsey LTD. ) | |||
Tek 545b trace.jpg | 545B with [[M|Type M plug-in]] | |||
Tek 545b right.jpg | 545B right side | |||
Tek 545b trace2.jpg | 545B with 1A1 | |||
545b_vertical.png | 545B signal path | |||
Tek 545b top.jpg | 545B top | |||
Tek 545b rear.jpg | 545B rear | |||
Tek 545b right internal.jpg | 545B right internal | |||
Tek 545b vert output.jpg | 545B vertical output stage | |||
Tek 545 vertical2.jpg | 545B vertical output stage | |||
Tek 545b block.png | 545B Block Diagram | |||
Tek 545b power supply.png | 545B Power Supply | |||
Tek 545b hvps.png | 545B High Voltage Power Supply | |||
Tek 545b calibrator.png | 545B Calibrator | |||
Tek 545b trigger a.png | 545B Trigger A | |||
Tek 545b timebase a 1.png | 545B Timebase A | |||
Tek 545b trigger b.png | 545B Trigger B | |||
Tek 545b timebase b.png | 545B Timebase B | |||
Tek 545b horiz amp.png | 545B Horizontal Amp | |||
Tek 545b front.jpg | 545B with [[1S2]] | |||
Tek 545b left internal.jpg | 545B left internal | |||
Tek 545b right internal.jpg | 545B right internal | |||
Tek 545b left external.jpg | 545B left external | |||
Tek 545 right external.jpg | 545B right external | |||
Tek 545b top external.jpg | 545B top external | |||
Tek 545b 1div squarewave.jpg | 545B Squarewave | |||
</gallery> | </gallery> | ||
===RM545B=== | |||
<gallery> | |||
Rm545b.JPG |RM545B | |||
</gallery> | |||
==Components== | |||
{{Parts|545}} | |||
{{Parts|RM45}} | |||
{{Parts|545A}} | |||
{{Parts|545B}} | |||
{{Parts|RM545B}} | |||
[[Category:500 series scopes]] | |||
[[Category:Introduced in 1955]] |