AWG520: Difference between revisions
Jump to navigation
Jump to search
Jaredcabot (talk | contribs) (Added photo) |
No edit summary |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 11: | Line 11: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:071-0099-51.pdf|AWG510/AWG520 User Manual 071-0099-51]] | * [[Media:071-0099-51.pdf|AWG510/AWG520 User Manual 071-0099-51]] | ||
* [[Media:071-0101-50.pdf|AWG510/AWG520 Service Manual 071-0101-50]] | * [[Media:071-0101-50.pdf|AWG510/AWG520 Service Manual 071-0101-50]] | ||
* [[Media:075-0263-50.pdf|AWG510/AWG520 Rackmount Kit Manual 075-0263-50]] | * [[Media:071-1500-00.pdf|AWG520 Option 11 Removable HDD User Guide 071-1500-00]] | ||
* [[Media:070-A810-50.pdf| | * [[Media:071-1501-00.pdf|AWG520 Option 11 Removable HDD User Guide 071-1501-00]] | ||
* [[Media:075-0263-50.pdf|AWG510/AWG520 Rackmount Kit Manual 075-0263-50]] | |||
* [[Media:071-0100-00.pdf|AWG500/600/700 Programmer Manual 071-0100-00]] | |||
* [[Media:070-A810-50.pdf|AWG500/600/700 Programmer Manual 070-A810-50]] | |||
* [[Media:075-0829-00.pdf|AWG520 AWG5UP Option 11 Install Manual 075-0829-00]] | |||
* [[Media:075-0890-00.pdf|AWG520 AWG5UP Option 10 Install Manual 075-0890-00]] | |||
* [[Media:76W_11846_5_1.pdf|AWG520 Sales Brochure]] | |||
}} | }} | ||
The '''Tektronix AWG520''' is a two channel arbitrary waveform generator. | The '''Tektronix AWG520''' is a two channel arbitrary waveform generator. | ||
Line 36: | Line 42: | ||
==Software== | ==Software== | ||
* [[Media:Awgcnvt104.zip|AWG400/500/600/700 Conversion Utility - Converts ASCII and AWG2000 Series file formats.]] (ZIP) | * [[Media:Awgcnvt104.zip|AWG400/500/600/700 Conversion Utility - Converts ASCII and AWG2000 Series file formats. 066-0089-00]] (ZIP) | ||
* [[Media:ArbLink.zip|ARB-Link Waveform Creation Utility]] (ZIP) | * [[Media:ArbLink.zip|ARB-Link Waveform Creation Utility 062-A270-50]] (ZIP) | ||
* [[Media:MCIQ.ZIP|Multi-Carrier IQ Generator - MCIQ. Create digitally modulated signals and waveforms]] (ZIP) | * [[Media:MCIQ.ZIP|Multi-Carrier IQ Generator - MCIQ. Create digitally modulated signals and waveforms 066-0405-00]] (ZIP) | ||
* [[Media:WaveWriter4 01E.zip|Wavewriter software Win3.1, 95, 98, NT4]] (ZIP) | * [[Media:WaveWriter4 01E.zip|Wavewriter software Win3.1, 95, 98, NT4 100-0000-064]] (ZIP) | ||
* [[Media:AWGandAFGLabVIEWExamples.zip|Labview Examples]] (ZIP) | * [[Media:070-8401-04.pdf|Tektronix WaveWriter (AWE) User Manual]] | ||
* [[Media:AWGandAFGLabVIEWExamples.zip|Labview Examples 066-TSC1-01]] (ZIP) | |||
==Standard Accessory Floppy Disks== | ==Standard Accessory Floppy Disks== | ||
Line 48: | Line 55: | ||
==Firmware== | ==Firmware== | ||
* [[Media:AW50P23.zip|AWG500 Series Program Upgrade v2.3]] (ZIP) | * [[Media:AW50P23.zip|AWG500 Series Program Upgrade v2.3 066-0068-00]] (ZIP) | ||
* [[Media:AW50P40.zip|AWG500 Series Program Upgrade v4.0]] (ZIP) | * [[Media:AW50P40.zip|AWG500 Series Program Upgrade v4.0 066-A002-50]] (ZIP) | ||
==Options== | ==Options== | ||
Line 94: | Line 101: | ||
** [https://www.eevblog.com/forum/repair/sonytektronix-awg520-2ch-1gss-with-no-output-repair-attempt-and-teardown/msg4121044/#msg4121044 Replacing disk drives with CF cards and updating operating system] | ** [https://www.eevblog.com/forum/repair/sonytektronix-awg520-2ch-1gss-with-no-output-repair-attempt-and-teardown/msg4121044/#msg4121044 Replacing disk drives with CF cards and updating operating system] | ||
==Photos== | |||
<gallery> | |||
AWG520_Front02.jpg | |||
AWG520_Left.jpg | |||
AWG520_Rear.jpg | |||
AWG520_Right.jpg | |||
AWG520_Underside.jpg | |||
</gallery> | |||
[[Category:Arbitrary waveform generators]] | [[Category:Arbitrary waveform generators]] |
Latest revision as of 05:15, 9 June 2024
The Tektronix AWG520 is a two channel arbitrary waveform generator.
Key Specifications
Sampling Frequency | 50 MHz to 1 GHz, 8 digits resolution, ±1 ppm within 1 year (25 °C) |
---|---|
Waveform memory | 4,194,048 10-bit words |
Marker memory | 4,194,048 words (4 markers x 1 bit) |
Sequence memory | Maximum 8000 steps |
Sequence counter | 1 to 65536, or infinite |
Waveform data points | 256 – 4,194,048 points (multiple of 4) |
D/A resolution | 10 bits |
Phase noise, typical | @ 1 GHz: –80 dBc/Hz (10 kHz offset), –100 dBc/Hz (100 kHz offset) |
Output Impedance | 50 Ω |
Amplitude range | 20 mVp-p to 2 Vp-p, 1 mV resolution, Offset –2 V to +2 V, into a 50 Ω load |
Rise/fall time | ≤ 2.5 ns (amplitude > 1.0 V p-p), ≤ 1.7 ns (amplitude ≤ 1.0 V p-p) (10% to 90%) |
Power | 90–250 VAC, 48–63 Hz, 600 W (standard) |
Dimensions | 194 mm (7.64") x 434 mm (17.1") x 602 mm (23.71"), H×W×L |
Net Weight | 17 kg (37.5 lb) |
Software
- AWG400/500/600/700 Conversion Utility - Converts ASCII and AWG2000 Series file formats. 066-0089-00 (ZIP)
- ARB-Link Waveform Creation Utility 062-A270-50 (ZIP)
- Multi-Carrier IQ Generator - MCIQ. Create digitally modulated signals and waveforms 066-0405-00 (ZIP)
- Wavewriter software Win3.1, 95, 98, NT4 100-0000-064 (ZIP)
- Tektronix WaveWriter (AWE) User Manual
- Labview Examples 066-TSC1-01 (ZIP)
Standard Accessory Floppy Disks
- AWG500 Series Sample Waveforms Disk 063-2981-00 (ZIP)
- AWG500 Series GPIB Sample Program Disk 063-2982-00 (ZIP)
- AWG500 Performance Verification Disk 063-2983-50 (ZIP)
Firmware
- AWG500 Series Program Upgrade v2.3 066-0068-00 (ZIP)
- AWG500 Series Program Upgrade v4.0 066-A002-50 (ZIP)
Options
- A1 - Universal European power cord
- A2 - UK power cord
- A3 - Australian power cord
- A4 - North American power cord
- A5 - Switzerland power cord
- 03 - Digital data out
- 1R - Rackmount
- 1S - WaveWriter S3FTx00 Software
- 10 - 78 MByte Flash Disk (replaces Hard disk)
- D1 - Certificate with Calibration Data
Optional Accessories
- 071-0101-XX - Service Manual
- 200-3696-01 - Front Cover
- 016-1675-XX - Rack Mount Kit (for field conversion)
- 012-0991-00 - GPIB cable
- 012-1342-00 - BNC cable, 50 Ω
- 012-1256-00 - BNC cable, 50 Ω, double-shield
- 012-1458-00 - SMB cable, 50 Ω
- 012-1459-00 - SMB-to-BNC cable, 50 Ω
- 011-0049-02 = BNC terminator, 50 Ω
- 015-0660-00 - BNC power divider, 50 Ω, DC to 300 MHz, VSWR: 1.2 max.
- 015-0659-00 - BNC low pass filter, 400 MHz
- 015-0658-00 - BNC low pass filter, 200 MHz
- 015-0657-00 - BNC low pass filter, 100 MHz
Standard Accessories
- 071-0099-51 - User Manual
- 070-A810-50 - Programmer Manual
- 063-2981-XX - Sample waveform floppy disk, 3.5 inch
- 063-2982-XX - GPIB sample program floppy disk, 3.5 inch
- 063-2983-XX - Performance check/adjustment floppy disk 3.5 inch
- 063-3763-XX - Arb-Express Software Package
- 061-4288-XX - Arb-Express Software Package, Instructions
- 159-0407-00 - Fuse, 10 A FAST (UL198G, 3AG) (installed to the instrument)
- 200-2264-00 - Fuse cap (installed to the instrument)
- 161-0232-01 - U.S. Power Cord
Links
- EEVBlog Forum Threads: