* [ | {{Probe Sidebar | ||
|manufacturer=Tektronix | |||
|model=P6006 | |||
|summary=25 MHz, 10× passive probe | |||
|image=Tek p6006 1.JPG | |||
|caption=Tektronix P6006 | |||
|for=1 MΩ scope inputs | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:070-0381-00.pdf|Tektronix P6006 Manual]] | |||
}} | |||
The '''Tektronix P6006''' is a 10X passive scope probe for 1 MΩ scope inputs. Versions were made with 3½, 6, 9, and 12 foot cables. | |||
Versions with both [[BNC]] and [[UHF]] connectors were available. | |||
{{BeginSpecs}} | |||
{{Spec | Attenuation | 10× ±3% with 1 MΩ ±2% scope input }} | |||
{{Spec | Maximum Voltage | 600 V, DC + peak AC, derated with frequency }} | |||
{{Spec | Compensation range | 15 pF to 55 pF }} | |||
{{Spec | Bandwidth | ~25 MHz w/20 pF scope inputs }} | |||
{{Spec | Input capacitance | 7.5-15.5 pF, depending on cable length and scope input capacitance }} | |||
{{EndSpecs}} | |||
<gallery> | |||
Tek p6006 1.JPG | |||
Tek p6006 2.JPG | |||
Tek p6006 3.JPG | |||
P6006-01.jpg | P6006 Probe close-up | |||
P6006-02.jpg | P6006 Probe with 013-0071-00 Screw-on clip adapter | |||
TekP6006-03.jpg | P6006 Probe with BNC connector | |||
</gallery> | |||
[[Category:1 MΩ Oscilloscope probes]] | |||
[[Category:6-32 probes]] |
Latest revision as of 13:11, 13 August 2024
The Tektronix P6006 is a 10X passive scope probe for 1 MΩ scope inputs. Versions were made with 3½, 6, 9, and 12 foot cables. Versions with both BNC and UHF connectors were available.
Key Specifications
Attenuation | 10× ±3% with 1 MΩ ±2% scope input |
---|---|
Maximum Voltage | 600 V, DC + peak AC, derated with frequency |
Compensation range | 15 pF to 55 pF |
Bandwidth | ~25 MHz w/20 pF scope inputs |
Input capacitance | 7.5-15.5 pF, depending on cable length and scope input capacitance |
-
-
-
-
P6006 Probe close-up
-
P6006 Probe with 013-0071-00 Screw-on clip adapter
-