(Created page with "1481R Vertical Scan fault whereby v scan is crushed as position is moved up. Corrected by replacing Q1617 (used to hand 2N2891 to replace 151-044600) 1481C No video, just horizontal line Noted that many semiconductors on vid/vscan board are in sockets (presumably for easy selection on test). By wiggling these socketed components in their sockets, video was restored.") |
No edit summary |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
1481R | 1481R - | ||
Vertical Scan fault whereby v scan is crushed as position is moved up. | Vertical Scan fault whereby v scan is crushed as position is moved up. Corrected by replacing Q1617 (used to hand 2N2891 to replace 151-044600). | ||
Corrected by replacing Q1617 (used to hand 2N2891 to replace 151-044600) | |||
1481C | 1481C - | ||
No video, just horizontal line | No video, just horizontal line. | ||
Noted that many semiconductors on vid/vscan board are in sockets (presumably for easy selection on test). | Noted that many semiconductors on vid/vscan board are in sockets (presumably for easy selection on test). | ||
By wiggling these socketed components in their sockets, video was restored. | By wiggling these socketed components in their sockets, video was restored. |